- Cheng Li, Mach Chen, Weiqiang Cheng, Rakesh Gandhi and Quan Xiong published RFC 10067 as a Standards Track extension for associated bidirectional SR LSPs.
- PCEP Association Type 8 groups two unidirectional SR LSPs while the PCE maintains two PLSP-IDs, one reported by each endpoint PCC. Co-routed and non-co-routed pairs are allowed.
- The RFC adds no liveness mechanism or MIB object and reports no deployment or failure data. Operators still have to correlate forward and reverse evidence at the management layer.
One relationship, two surviving LSPs
The word “bidirectional” sounds as if two paths disappear into one. RFC 10067 does not perform that merger. It creates a relationship with Association Type 8 between two unidirectional Segment Routing LSPs, then keeps each path’s PCEP identity.
The ingress PCC reports one PLSP-ID. The egress PCC reports another. The PCE maintains both. The RFC’s examples use 100 and 200, a simple reminder that one association still has two independently addressable ends, two sets of path state and two places where an update may fail.
This distinction matters when a controller shows “bidirectional LSP: up.” The display may describe an association record. It may describe one direction’s state. It may describe the existence of reverse EROs. Those are not the same as a completed packet path in each direction.
Who initiates does not erase who reports
A Stateful PCE can initiate the two SR LSPs and send each associated reverse ERO. Each PCC then assigns a local PLSP-ID and reports it. In the PCC-initiated case, the endpoints first report or delegate their LSPs, and the PCE later updates the pair with reverse EROs.
The association does not transfer local identity to the controller. It gives both sides a common Relationship. The RFC 8231 stateful PCEP model still gives the PCC its local LSP identity, while RFC 8697 supplies the association-group machinery.
Before any of this works, the PCEP speaker must advertise the Bidirectional SR LSP Association type and receive the same capability from its peer. A controller with the right code and the wrong negotiated capability has an unsupported association, not an implicitly enabled feature.
The flags catch contradictory promises
RFC 10067 reuses earlier structures carefully. The optional Bidirectional LSP Association Group TLV can mark a co-routed pair with the C flag. Reverse EROs are identified by PATH-ATTRIB R=1. The optional MULTIPATH-OPPDIR-PATH TLV can carry properties for that reverse path.
The flags exist because the pair can be non-co-routed. A forward and reverse path may use different links or nodes. Copying the forward route into a reverse slot would make a tidy diagram and a false topology claim.
The association rejects contradictions. One SR LSP cannot join more than one such association on the PCE. When that happens, the PCE must not send the associated reverse EROs, and it must log the error and raise an alarm. The Reverse LSP R flag must not be set, because RFC 10067 does not instantiate a reverse SR LSP object. A mismatch between reverse-path properties and the association’s C flag is also logged and alarmed.
The Path Setup Type must be SR value 1 or SRv6 value 3. Any other type paired with this association triggers PCErr Error-Type 26, Error-value 16. The protocol catches the mismatch instead of hoping the data plane discovers it later.
Two live directions make one working service
RFC 10067 adds no liveness method. Forward and reverse sides are monitored separately. The operator must correlate their evidence to decide whether the bidirectional service is operating. Directed BFD and Performance Measurement may provide those observations, but neither turns one green direction into two.
The management model is also incomplete. The RFC says the PCEP YANG model does not cover these associations and suggests fields for support, enablement and success or failure counters. The document adds no MIB object and no new control-policy requirement.
IANA assigns Association Type 8. The RFC recommends TLS for PCEP because a malicious PCEP speaker belongs in the threat model. No implementation census or field incident is supplied. A dated deployment report would change how urgent these checks are.
The useful receipt is deliberately longer than the headline: association type, capability negotiation, both PLSP-IDs, both EROs, the reverse and co-routing flags, one result per direction, management correlation and the alarm history. “Bidirectional” is the relationship. The two independently verified paths are the service.
Sources: RFC 10067; RFC 10066; RFC 9059; RFC 8231; RFC 8697; IANA PCEP registry; Cheng Li IETF profile. Related PCEP and SRv6 references: RFC 8664; RFC 9603.
Member Briefing
Read the full trend briefing
Members read the full briefing with the source notes behind every finding.
Strategic Circle
A daily briefing in your language, built from changes we have verified.
Join for USD 20/monthCancel anytime.
Members also get the full research library, a daily briefing on the networks they follow and the private forum.