Summary

  • At 30 September 2026 Indus Towers reported 270,480 macro towers, 440,153 macro co-locations and a sharing factor printed twice: 1.62 on average, 1.63 at the close.
  • Its energy figures are rupees per site, and they are one expense total divided twice; the kilowatts, autonomy hours and litres that would bound a site appear in none of the sixteen documents reviewed on 25 November 2026.
  • TRAI's only per-site diesel figure, 8,760 litres a tower a year, is exactly the number of hours in a year.

A tower is sold by the tenant-month

The unit of this business is not the mast. It is the tenancy: one operator's active equipment on one structure, billed monthly, with the operator owning the antennas and base station and Indus supplying space and power, on leases of more than seven years with exit penalties (Annual Report 2023-24).

That unit has a price and a count. At 30 September 2026 the count was 440,153 macro co-locations on 270,480 macro towers, with 14,037 lean co-locations on top, which is 454,190 if you add them. Net macro adds in the quarter were 7,903 and exits 472 (quarterly report). The price was Rs 66,532 a tower a month and Rs 41,036 a sharing operator a month, with lean co-locations earning Rs 16,867 an operator (press release).

The company prints two sharing factors and they are not rivals. The average, 1.62, is a period quantity; the closing figure, 1.63, is a point-in-time one. Divide the closing counts and you get 440,153 ÷ 270,480 = 1.6273, which rounds to 1.63. Mine, not printed. Anyone who reads 1.62 against 1.63 as a contradiction has misread two different measures of the same estate.

What is genuinely absent is the ceiling. A tenancy is added when someone decides the structure can hold another antenna frame and the site can supply another load. That decision has an input in kilowatts, hours and kilograms. No page in the reviewed set prints it.

One rupee total, divided twice

The second stream is where the physical world leaks into the accounts. In the quarter, revenue from operations was Rs 85,150 million: Rs 54,410 million of sharing revenue, Rs 30,696 million of energy reimbursements and Rs 44 million from goods and services. Power and fuel cost Rs 31,831 million, 82 per cent of operating expenses (quarterly report).

Energy is then printed per site: Rs 39,437 a tower a month, Rs 24,324 a co-location a month. Cost other than energy is Rs 8,592 and Rs 5,300. Those four figures share one implied ratio — 66,532 ÷ 41,036 = 1.6213, 39,437 ÷ 24,324 = 1.6213, 8,592 ÷ 5,300 = 1.6211 — which is the average sharing factor, not the closing one. They are one rupee total divided twice, not two measurements.

Mine, and the check is that rebuilding the expense line from either set lands on the printed total: Rs 39,437 × 270,480 towers × 3 months is about Rs 31,994 million and Rs 24,324 × 440,153 co-locations × 3 months is about Rs 32,119 million, against the printed Rs 31,831 million, an overshoot of 0.51 and 0.90 per cent from rounding to the rupee.

The printed energy margin is negative 3.6 per cent, against negative 4.6 per cent in the previous quarter and negative 4.8 per cent a year earlier (call transcript). The label does not say which base it uses. Mine: the rupee gap is Rs 1,135 million, which is 3.57 per cent of the expense and 3.70 per cent of the reimbursement. Neither number is a mispricing finding. Both say the pass-through recovers a little less than it spends.

Management's own description of growth is telling: an incremental co-location is "basically a second tenant on an existing site" (transcript). That is a business model, not a headroom measurement. The sentence that would matter — the one naming what the site's power arrangement and steel can still take — is not in the transcript.

What the state does print

Indian telecom regulation prints exactly one physical quantity about a base station: an emission ceiling. The general-public limit is a power density of f/2000 watts per square metre from 400 MHz to 2 GHz, with f in MHz, and 1 W/m² from 2 to 300 GHz, with E-field limits of 0.434 × √f V/m and 19.29 V/m and H-field limits of 0.0011 × √f A/m and 0.05 A/m. DoT adopted ICNIRP through an Access Service Licence amendment dated 4 November 2008, tightened the reference levels to one tenth, and enforced them through directions of 30 December 2011 revised on 10 January and 26 June 2013, with biennial self-certification (DoT EMF page).

That single quantity is printed three incompatible ways at 2100 MHz. The formula gives 1.05 W/m². The advisory to states effective 1 August 2013 prints a flat 1 W/m² at 2100 MHz and above, with 0.45 at 900 and 0.9 at 1800 (DoT advisory). The July 2022 study paper's country table prints 1.1 (DoT study paper). Mine: converting the table's own 19.29 V/m through S = E²/377 reproduces 0.45 at 900 MHz and 0.90 at 1800 MHz exactly, and lands at about 0.99 at 2100 — on the flat row, not the formula. Three values, one band, no declaration of which governs. I print all three and average none.

Everything else the state says about a site is an assumption with a date on it. TRAI's April 2011 recommendations put average consumption at 3 to 4 kW a tower and diesel at 8,760 litres a tower a year on eight hours of generator running a day, inside an estimate of about 10 million tonnes of CO2 (TRAI 2011). Eight hours a day is 2,920 hours, so 8,760 litres requires 3 litres an hour. 8,760 is also exactly the hours in a year, which means the same figure read as 1 litre an hour around the clock needs all of them. Mine, and it matters: the only per-site diesel figure in Indian telecom regulation is a construction, and the same regulator's 2017 methodology prints 3 litres an hour for a 15 kVA set (TRAI 2017) while a 2013 DoT presentation prints 1 to 3 kW, 15 to 20 kVA generators, 4 litres an hour and 8 to 16 running hours a day (DoT, ITU symposium), which at eight hours is 11,680 litres.

The 2017 recommendations ask for total litres by licensed service area and quarter, self-certified, with no third-party audit, and call for new builds to be diesel-free "to the extent feasible" — without printing an autonomy in hours, a litres-per-site requirement or a kilowatts-per-site figure in the text reviewed. The DoT Infrastructure Provider Category-I guidelines define the business as dark fibre, right of way, duct space and tower and impose no electrical specification in the retrieved text (IP-I guidelines). The one document that says plainly where the missing number lives is TEC's solar power-supply generic requirement: battery voltage and capacity depend on the load voltage, the optimum load and the autonomy, with the autonomy an ordering parameter and 80 per cent capacity reserved for sunless days (TEC GR 66100).

That is the control surface. The number is not missing. It is held by whoever orders the site.

What the company does print, and what it puts in gigajoules

Indus prints energy in rupees per site and, once a year, in gigajoules company-wide. The FY26 BRSR, with reasonable assurance of BRSR Core by SGS India, gives renewable 733,454 GJ against 368,736 a year earlier, non-renewable electricity 36,381,696 GJ against 33,315,933 and non-renewable fuel 2,340,785 GJ against 2,300,513, plus Scope 1 emissions of 698,399 tCO2e and Scope 2 of 7,175,689 (BRSR FY26). The three assured lines sum to 39,455,935 GJ against 35,985,182 GJ, a ratio of 1.0964. Mine: that re-derives the company's own narrative figure of 9.6 per cent, which is the useful thing a closed sum does — it tells you the three lines cover the same perimeter and the same year. Inside that total, renewable energy is 1.86 per cent, non-renewable electricity 92.21 per cent and fuel 5.93 per cent.

The narrative that accompanies the FY26 report states changes only: overall energy up 9.6 per cent, diesel up about 2 per cent, diesel per tower down 8.5 per cent, diesel down 16 per cent against the FY22 base, about 42,400 solar-powered sites and about 212,000 sites on the iDOT platform (FY26 integrated report filing). The same filing is the only reviewed Indus document that enumerates what a tower is: traditional ground or rooftop towers and poles, hybrid, monopole and camouflaged towers, in-building DAS and small cells, smart poles; and it states that design, capacity and utilisation parameters were integrated into a centralised digital platform to speed upgrade and co-location approvals. A platform that holds the design capacity is a strong hint about where the ceiling is written down. The filing does not print it.

What the annual volume implies about a site is an illustration, not a measurement, and I label it as mine. Converting 39,455,935 GJ at 3.6 GJ per MWh gives about 10,959,982 MWh, which averaged over the 8,760 hours of the year is about 1,251 MW. Over 264,514 towers at 31 March 2026 that is about 4.73 kW a tower; over 270,480 towers at 30 September 2026, about 4.63 kW. That spans an annual energy total, a year-end stock and a stock six months later, so it is an order-of-magnitude average. It sits above TRAI's 3 to 4 kW and above the 1 to 3 kW on the 2013 DoT slide, and inside the 1 to 8.5 kW band that the 2012 GSMA paper describes for Indian sites, with more than 80 per cent of configurations below 3.5 kW, 10 to 15 kVA generators, 300 to 900 Ah battery banks and a worked three-base-station case at 2.52 kW with four battery run-hours (GSMA 2012). Those are descriptions and estimation assumptions, not specifications.

Boundaries, and what would change this reading

The reviewed set is sixteen documents read on 25 November 2026: seven Indus filings and reports (the Q2 FY27 quarterly report, press release and earnings call transcript; the FY2025-26 integrated report letter and FY26 BRSR; the Annual Report 2023-24), one prior BTW article of 20 November 2026, three DoT EMF documents, three TRAI documents, the DoT IP-I registration guidelines, TEC's solar power-supply requirement, a DoT presentation at an ITU symposium in May 2013 and the 2012 GSMA site-energy paper. Every absence here is a count over those sixteen documents on that date.

It is not a claim that a figure is published nowhere, and not a claim that an unread document does not exist. Most long filings were read through search-index extracted text rather than page by page, and the grade is recorded per source; no claim rests on a page that was not surfaced.

Four dates are never conflated: 30 September 2026 for the quarter, 31 March 2026 for the financial year, 31 March 2025 for the prior year, and 25 November 2026 for the reading. The 440,153 macro co-locations and the 454,190 including lean are never mixed when discussing the sharing factor or revenue per operator; lean co-locations earn their own separate per-operator figure. A power density in watts per square metre is an emission limit, not a load on a site's power supply, and I do not use it as a bound on tenancies.

The 2012 GSMA configurations and the 2011 and 2013 official figures are descriptions and estimation assumptions; the TEC requirement is an equipment generic requirement, not a licence condition for a tower.

Prior BTW coverage established the two-stream structure: of Rs 301,228 million of FY2025 revenue from operations, Rs 191,974 million was sharing revenue and Rs 109,199 million energy and other reimbursements, with the second stream running at a negative margin (BTW, 20 November 2026). This briefing does not repeat that. It takes the tenancy as the unit of sale and asks what bounds it, which is why the earlier piece is a starting point and not the answer.

The falsifier is concrete. Name a reviewed page that prints, for the same estate and date, both the achieved tenancy ratio and a physical ceiling in kilowatts, autonomy hours, litres or mounting capacity. If such a page exists in the sixteen documents cited here, the central absence claim fails and this article has to be rewritten around it.

The bill is for an unreliability nobody quantities

A tower company that prices its asset by the tenant-month and its energy by the rupee has made an honest choice about units. It has also made the site's physical limit invisible to everyone outside the engineering file. The FY26 numbers show a business adding tenancies faster than the ratio moves, on a structure whose load, autonomy and mounting capacity are set at ordering and disclosed to no one in the reviewed record.

So the useful questions are not about the ratio. They are: who ordered this site, what autonomy did that order specify, what load did the power arrangement assume, and what did the steel allow? A tenant signing a seven-year lease, a lender underwriting a tower book and a regulator writing a diesel rule are all buying the answer to those questions without being able to read it. The energy margin of negative 3.6 per cent is the visible half of that arrangement — a bill for grid unreliability, settled in rupees, never quantified per site in kilowatt-hours, litres or hours.