Summary

  • RIPE Labs researchers trained a BGP detector on public RIS data for one network, then ran it unchanged over 864 unseen five-minute windows. It raised six alerts; four covered a 65-minute routing event that the network’s operations team confirmed.
  • The same model detected the Iberian blackout’s routing breakdown at 16:10 UTC on 28 April 2025. The grid failed at 10:33 UTC. BGP stayed quiet while routers remained on backup power.
  • The detector flagged 63 of 84 windows in the disruption period, 75%, and five of 395 windows outside it. It must be fitted to network shape: moving a model between a dense and a sparse network lowered its macro-F1 score from about 0.87 to 0.40–0.70.

A control-plane alarm is not a universal incident detector. It is a statement that one collector’s view of routing changed in a way that its trained model did not expect. That distinction makes the RIPE Labs study useful. It does not package an AI model as an all-seeing NOC. It measures when the alarm fired, what an operator could confirm and which view the model had.

The blind test involved a European national research and education network. The researcher used one month of public RIS data from a collector near the network to learn its normal behaviour. The following month, the unchanged model scored 864 five-minute windows over three days.

It raised six alarms. Four fell within 65 minutes of one another on the second morning. The other two appeared at a similar time on the first and third days and were attributed to recurring collector activity. The researchers counted them as false alerts.

For the four-alert episode, the operations team received timestamps and no model explanation. It checked its own monitoring and found an upstream routing change, a withdrawal burst and reconvergence. Service stayed up. Only after that confirmation did the team receive the signals behind the alarm: about 60% of updates in the flagged windows involved the network’s neighbourhood, against about 26% normally, and two windows contained 229–245 route flaps against a normal average near 40.

That is a successful validation with a narrow boundary. The operator confirmed that the flagged event happened. Nobody checked whether an important routing event occurred elsewhere in the 864 windows and produced no alert. A detector can look clever after a confirmed alarm; a monitoring programme needs its misses too.

BGP did not know the lights had gone out

The second test supplies the harder lesson. The Iberian grid failed at 10:33 UTC on 28 April 2025. Routers with battery-backed power kept forwarding, so BGP did not react. Routing began to break around 16:00 UTC. The first alarm from AS3352’s model arrived ten minutes later. The power event was five hours and 37 minutes old; the routing event was ten minutes old.

That delay is not a software bug. BGP carries reachability, not electricity. The detector watches updates and the network’s peering map. During the first hours of the blackout, neither moved enough to cross its threshold. When the surrounding topology began coming apart, the graph-aware model caught it.

For the 16:00–23:00 UTC disruption, the model flagged 63 of 84 five-minute windows. Twenty-one windows remained unflagged. Outside the period it raised five alarms in 395 windows, 1.3%, including alarms near the boundaries where routing was still unstable. Those are strong aggregate results for one network and one event, not a guarantee that every 25% of unflagged windows represented missed routing damage.

The control-plane lag matters to incident response. A NOC that waits for BGP to move will miss failures hidden by UPS systems, regional isolation, application collapse and traffic shifts that do not immediately alter route selection. A system that waits for power telemetry will miss routing incidents with healthy facilities. Useful detection needs a timeline that includes both.

The model does not travel well

The RIPE Labs account is also honest about transfer. For one network, training and testing against a different RIS collector produced a macro-F1 score around 0.87. The vantage point mattered much less than the network’s shape. Moving between AS3352’s dense mesh and AS12880’s sparse gateway structure dropped the score to 0.40–0.70.

The practical consequence is blunt: a vendor or research model with an impressive benchmark on a large transit network has not passed a test on a two-upstream access ISP. A model tuned for a sparse star may treat ordinary changes in a dense mesh as chaos. A graph model trained on a mesh may miss a small network because its normal variation is too thin.

The researchers used one month of a network’s data to train candidates and selected a model for that topology. A detector used across a portfolio needs separate validation, labelled incidents and a way to update the baseline when the network changes.

Build the receipt that proves the alarm was useful

The next record should bind five times: when the underlying service failed, when its traffic or facilities changed, when BGP changed, when the detector scored the window and when the NOC confirmed the incident. It should record the RIS collector, the network view, the alert threshold, the signals that triggered the score, the operator’s disposition and whether a later review found an unalerted event.

That ledger tells management more than a model accuracy score. It shows whether the detector anticipates customer impact, follows it or arrives after the workaround. It distinguishes a useful early warning from a late explanation of a fault the operator already knew.

RIPE Labs has invited operators to test the detector against public RIS data without exposing router logs or traffic. The offer is useful because the evidence is still thin: one confirmed blind-test event, one major outage and three networks used to describe the topology rule. More tests will make the model better. Honest timing will make the alerts usable.

Sources: RIPE Labs blind test; RIPE RIS.