Summary
- The 7800R4 prints 173 billion packets a second beside 460.8 Tbps of 800-gigabit ports. Divide them and the frame is 333.3 bytes; divide the same wire at the 84-byte minimum frame and the printed rate is 25.2 per cent of it.
- Six divisions across eleven Arista data sheets imply six packet sizes: 83.3 bytes on the 2009 7048, 84.0 on the 7260CX-64, 121.2 on the 7060CX-32S, 190.5 on the 7260CX3-64, exactly 200.0 on the 7050CX3-32S and the 7060X4, and 333.3 on the 7800R4 line card. That is a spread of four times, computed from the sheets' own cells.
- Three of the eleven documents print any packet-size condition, and all three print it in the footnote attached to the power row: 200 bytes on the 7060X4 and the 7050QX, 128 bytes on the 7260X3. No footnote in the read set marks a packets-per-second cell.
- The condition fits in the sentence that carries the rate. Two Cisco Nexus 5600 sheets print "1071 million packets per second (mpps; 64-byte packets)" and "1428 mpps (64-byte packets)", and both reproduce at 672.3 bits against their one-direction port sums.
The two rows are one row
A switch data sheet is read as a specification. Somewhere in it, two lines apart, sit a capacity in terabits per second and a forwarding rate in packets per second, and the convention of reading turns them into two properties of one box: how much it can carry, and how fast it can think.
They are not two properties. A bit rate and a frame rate are the same bandwidth divided by the size of a frame, and nothing else. Fix the frame at 64 bytes and a terabit per second is 1.4881 million packets; fix it at 200 bytes and the same terabit is 0.4762 million; fix it at 333 bytes and it is 0.2859 million. The division is not an interpretation of the sheet, it is the sheet's second number written the other way round. So a packet rate without a packet size is not a second capability, it is a bandwidth that has momentarily forgotten its units.
What follows is not a hunt for an error. Every figure divided below is a figure somebody can defend: at 200-byte packets the 7060X4 does carry 8 billion a second, and at 84 bytes it carries 19.05 billion. The point is that the sheet prints the smaller number, attaches no size to it, and thereby lets the reader infer a frame that the same sheet's port count cannot support at that rate.
The 7060CX-32S, the 7260X3, the 7050X3, the 7060X4, the 7800R4 and the 7048 are read below from the eleven Arista documents and two Cisco documents named at each claim, with four references for the frame's own construction. The set is eighteen documents read on 26 November 2026, five of the eleven Arista ones reached through third-party mirrors — HamburgNet and Andover CG for the 7260X3, Corporate Armor for the performance paper, data.nag.wiki for the 7048 — and a mirror may lag the seller's current file. Every absence counted here is counted over that set, not over the industry.
What a minimum frame actually weighs
Start with the smallest thing Ethernet can carry, because it decides what the largest possible packet rate is.
A minimum-size Ethernet transmission is not 64 bytes. The frame is 64 octets from the destination address through the frame check sequence; ahead of it run a seven-octet preamble and a one-octet start frame delimiter, and behind it a mandatory twelve octets of idle line state before the next frame may begin (the frame structure). The standards-track clause text puts the preamble and the delimiter outside the frame-size count, so the limits refer to the portion from destination address through frame check sequence inclusive (clause 3 of the MAC frame structure), and the working group's parameter table prints the pair the arithmetic needs: minimum frame size 512 bits, or 64 octets, beside an inter-frame gap of 96 bits (clause 99 parameter tables). That minimum is an IEEE 802.3 property; 802.3 is the collection of standards covering the physical layer and the media access control of wired Ethernet (IEEE 802.3). Both working-group documents behind the 512-bit and 96-bit figures are unapproved drafts on the public server, not clauses of a published edition, and the published edition was not read.
512 plus 64 plus 96 is 672 bits, or 84 bytes. A vendor's engineering page writes the same divisor as a formula, "Packets per second = (bits/second)/(bits/packet + IPG/packet)", and works one row of 512 bits of 64-byte packet plus 160 bits of interpacket gap per packet (Flexible Packet Processing Pipelines). The 160 bits is the twelve-octet gap bundled with the eight octets of preamble and delimiter, which is 672 bits again.
One terabit per second of one-direction capacity therefore carries 1,488,095,238 minimum-size packets a second, which is the 1.4881 million packets per second the arithmetic gives. It is a media-access-control rate: a port's line rate is higher, because 8b/10b coding at a gigabit and 64b/66b above it put more bits on the fibre than the frame contains. Everything divided below is at that level, and so is every implied packet size.
The direction convention decides the divisor
The 7800R4's throughput table is headed "Maximum Throughput (FDX)" and prints four pairs: 460 (920) Tbps, 345 (690), 230 (460) and 115 (230) (7800R4 AI Spine sheet). The port arithmetic puts the first element at the one-direction sum — 576 ports at 800 Gbps is 460.8 Tbps, as is 1,152 ports at 400 Gbps — so the parenthesised element is the doubled one. The header names a duplex quantity over a pair whose left-hand element is not duplex; that is a labelling habit, not a mistake, and the arithmetic is what resolves it.
The convention matters because the same constant cannot be used against both elements. Use 1.4881 against the one-direction figure and 0.7441 against the printed duplex figure, and the two are the same statement, differing by exactly two. Use 1.4881 against the duplex figure and every packet comes out twice the size the wire allows. The 7060X4 shows how the trap closes: its table prints "Throughput 25.6 Tbps" with no pair at all, so a reader who does not know that 25.6 is the bidirectional number divides 25.6e12 by 8e9, gets 3,200 bits, and concludes the sheet is rated at 400-byte packets — exactly twice the 200 bytes the same sheet's own footnote names (7060X4 data sheet). One factor of two, applied in the wrong place, and the sheet that does disclose its packet size becomes the sheet that seems to contradict itself.
Six divisions the sheets do not perform
What follows is my arithmetic, run on cells the documents print. For each platform the one-direction port sum is taken from the port count the sheet gives for that model; the packet rate is the cell as printed; the implied packet size is the first divided by the second; and the share is the printed rate divided by what the same ports carry at 672 bits.
| Platform and document | Throughput as printed | Port sum, one direction | Packets/second as printed | Implied bits per packet | Implied bytes | Share of the minimum-frame rate |
|---|---|---|---|---|---|---|
| 7800R4 line cards, AI Spine sheet | 28.8 (57.6) Tbps | 28.8 Tbps | 10.8 Bpps | 2,666.7 | 333.3 | 25.2% |
| 7060X4, both models | 25.6 Tbps | 12.8 Tbps | 8 Bpps | 1,600 | 200.0 | 42.0% |
| 7050CX3-32S, 7050X3 sheet | 3.2 (6.4) Tbps | 3.2 Tbps | 2 Bpps | 1,600 | 200.0 | 42.0% |
| 7260CX3-64, 7260X3 sheet | 6.4 (12.8) Tbps | 6.4 Tbps | 4.2 Bpps | 1,523.8 | 190.5 | 44.1% |
| 7060CX-32S, performance paper | 6.4 Tbps | 3.2 Tbps | 3.3 Bpps | 969.7 | 121.2 | 69.3% |
| 7260CX-64, performance paper | 12.8 Tbps | 6.4 Tbps | 9.52 Bpps | 672.3 | 84.0 | 100.0% |
| 7048, 2009 sheet | 88 Gbps | 88 Gbps | 132 Mpps | 666.7 | 83.3 | 101.0% |
The spread is 333.3 divided by 83.3, which is 4.00. One catalogue, one decade of documents, four times the packet.
Two rows deserve their own sentence, because they are the two ends of the argument. The 7048 is a 2009 leaf switch with 48 gigabit ports and four 10-gigabit ports, 88 Gbps in one direction, and it prints 132 million packets a second (7048 data sheet). That is 666.7 bits a packet, 83.3 bytes — a shade under the legal minimum, 101.0 per cent of what the ports can carry at 672 bits, which is rounding and a reminder that these cells are capability figures rather than line-rate divisions. The 7260CX-64 prints 12.8 Tbps and 9.52 billion packets a second (7060X and 7260X performance white paper); halve the throughput to one direction and 6.4e12 divided by 9.52e9 is 672.3 bits, 84.0 bytes, 100.0 per cent. At one end of the catalogue the packet rate is the worst case the wire permits, and at the other it is a quarter of it.
Nor is the rate a per-model division at all. The same white paper prints a Max Forwarding Rate of 3.3 billion packets a second against a 6.4 Tbps Max I/O Rate and again against a 5.12 Tbps row, and the 7060X and 7260X series sheet repeats 3.3 Bpps against 6.4 and 12.8 Tbps models in one table (7060X and 7260X series data sheet). One cell serving rows whose throughput differs by a factor of 2.56 cannot be a line-rate division for each of them, and at most one of those divisions can land on the wire minimum.
The footnote that admits the condition, and the row it is not attached to
Eleven Arista documents were read. Three of them print any packet-size condition. All three print it inside the footnote to the power row, and not one prints it on the packets-per-second row.
The 7060X4 note reads: "Typical power consumption measured at 25C ambient with 50% load. Performance rated over operation with average packets larger than 200 bytes." The 7050QX sheet carries the same sentence beside a 1440 Mpps cell (7050QX data sheet). The 7260X3 revision prints the variant with the smaller threshold: "Performance rated over operation with average packets larger than 128 bytes" (7260X3 data sheet, 2025 revision, and the earlier revision at the same page numbers (7260X3 sheet)).
So the sheet that discloses a 200-byte average is the same sheet whose 8 Bpps cell closes exactly at 200.0 bytes when the throughput is halved — the disclosure and the division agree to four figures. That is not a coincidence and it is worth saying plainly: the number was computed at a packet size, the packet size is knowable, and the sentence that carries it sits under a different row.
The 7048 makes the same point inside one table. Its latency row reads "Latency (64 byte packets) | 3 microseconds" and the row beneath it reads "Packets/Second | 132 Mpps" — a condition printed on one row and withheld from the row beside it, in a table whose two rows are about the same traffic. If the frame size could be assumed from context, the latency row would not need to say it.
What the other vendor prints in the same sentence
The condition fits in a sentence. The Cisco Nexus 5672UP-16G sheet states "Layer 2 and 3 hardware forwarding at 1.44 Tbps; 1071 million packets per second (mpps; 64-byte packets)" (Nexus 5600 10-Gbps data sheet), and the Nexus 5624Q sheet states "1.92 Tbps; 1428 mpps (64-byte packets)" (Nexus 5600 40-Gbps data sheet).
Both divide out at the wire minimum. The 5672UP-16G's 1.44 Tbps is a bidirectional number over 720 Gbps of one-direction port speed, and 720e9 divided by 1,071e6 is 672.3 bits. The 5624Q's 960 Gbps divided by 1,428e6 is 672.3 bits. Four significant figures, twice, from two sheets of one product line, in documents of the same class as the eleven above.
Neither of those sentences states a load, and neither says whether the 64 bytes includes preamble and gap; readers who want the worst case will assume it does, and the arithmetic above says it does. The point is narrower and harder to argue with: the disclosure is neither impossible nor unknown in this document class. It is a drafting choice, and one vendor made it. The comparison rests on two models of one product line: it establishes that stating the packet size inline is achievable in this document class, not that other vendors, or other lines of this one, do or do not do the same.
Where one sheet disagrees with itself
Two of the implied sizes are given above the size their own sheet names, and the gap is the size of the gap.
The 7260X3 rates performance over averages larger than 128 bytes and prints 4.2 Bpps against 6.4 Tbps of one-direction capacity. At 128 bytes a frame weighs 1,184 bits with the preamble and gap, so the 6.4 Tbps could carry 5,405 million such packets a second; the printed 4.2 billion is 77.7 per cent of that. At the printed rate, the frame is 1,523.8 bits, 190.5 bytes — 48.9 per cent more than the note's threshold, or, read the other way, the note's 128 bytes is 32.5 per cent below what the cell implies.
A note that says "larger than 128" and a cell that implies 190.5 describe a floor and a capability, and the sheet does not say which row each belongs to.
The 7050X3 family shows the same looseness one level down, and this one is worth following because it is a pure rounding artefact. The 3.2 Tbps model prints 2 Bpps, and 3.2e12 divided by 2e9 is 1,600 bits, 200.0 bytes (7050X3 data sheet). The 1.28 Tbps model prints 1 Bpps, and 1.28e12 divided by 1e9 is 1,280 bits, 160.0 bytes. Two models in one table, two implied sizes, one of which is the round number the other is not. The 7050X3's own architecture paper supplies the mode the table withholds — "In 25G cut-through mode, Arista 7050X3 switches forward packets with a consistent low latency of 800 nanoseconds" — and the buffer cell size that no other document in the set prints (7050X3 architecture paper).
A buffer printed in bytes and never in time
Buffers are the third quantity of the same kind. Six cells in the set read 16 MB, 22 MB, 32 MB, 42 MB, 64 MB and 32 GB, and no document among the eighteen divides one by a rate.
The division is mine, and it is the one a buyer needs. Using the one-direction port sum as the divisor, 32 MB at 3.2 Tbps drains in 80.0 microseconds; 42 MB at 6.4 Tbps in 52.5 microseconds; 64 MB at 12.8 Tbps in 40.0 microseconds; and the 7800R4 line card's 32 GB at 28.8 Tbps in 8.89 milliseconds. Taking the megabyte as a million bytes and the gigabyte as a thousand million, the byte figures span 32 MB to 32 GB, a factor of 1,000, while the times span 40.0 microseconds to 8.89 milliseconds, a factor of 222.
If the sheets mean 2^20 and 2^30, every time rises by 4.86 per cent or 7.37 per cent and the ordering does not change.
A buyer comparing "64 MB" with "32 GB" is comparing a byte count whose meaning depends on the port speed it is attached to. A buyer comparing 40 microseconds with 8.89 milliseconds is comparing what the box does to a burst. Only one of those comparisons is printed.
Latency is quoted at a frame, never at a load
The one place the 64-byte condition appears in a highlight is the one place it does least work. The 7800R4 AI Spine sheet says "Under 3 microsecond latency (64 bytes)"; the router sheet for the same chassis family says "Under 4 microsecond latency (64 bytes)" (7800R4 router sheet). One microsecond on a base of three is 33.3 per cent, for the same chassis, at the same stated frame size, in two documents a buyer would reasonably read as one product. Neither prints a load, a port speed or a traffic pattern. The line-card table beneath the router sheet's headline gives 2.8 microseconds for one card and 3.8 for the other two, which is the third version of the same number.
The 7260CX-64 carries a smaller version of the same gap: 500 to 1,500 nanoseconds in the performance paper, 550 to 1,500 in the data-sheet copy. Fifty nanoseconds at the lower bound is 10.0 per cent of 500, and the upper bound is identical, so one document's floor is the other's second value.
Where a sheet does state a condition, it states a frame size or a port type and never a load. The 7050X3's 3-microsecond row carries footnote 3, "Measured latency is for the 10GBase-T ports", and the architecture paper's 800 nanoseconds is qualified as 25G cut-through. In eighteen documents, no latency figure is printed beside an offered load.
This is the term the buyer has to add himself. Serialisation of a 672-bit minimum-size transmission costs 6.72 nanoseconds at 100 Gbps, 1.68 at 400 and 0.84 at 800. Serialisation of a 4,000-byte remote direct memory access write, 32,000 bits plus 160 of preamble and gap, costs 321.6, 80.4 and 40.2 nanoseconds at the same three speeds. The ratio between the two frames is 47.86. A latency quoted at 64 bytes and applied to a 4,000-byte write therefore omits a term roughly forty-eight times the one it states — not because the quoted figure is wrong, but because the frame it was measured on is not the frame the workload sends.
Oversubscription, asserted
The last quantity is the one that decides whether a fabric holds together, and it is the only one in the set that appears as prose rather than as a cell. The 7800R4 sheets describe a "non-blocking, fully scheduled and lossless VOQ cell-spraying architecture" and "100% efficient cell based load balancing". The 7050X3 writes that "With low latency and no oversubscription, the switch is optimized for high performance server and storage deployments".
Not one of the eighteen documents prints an oversubscription ratio as a number with a port basis: how many ports are assumed fully loaded in one direction, and how many in the other. The claim and its condition are both stated; the quantity between them is not. The only printed granularity in the set is the buffer cell size, 208 bytes, and that belongs to the 7050X3's architecture paper alone.
What to write into a tender
None of this requires a new standard. It requires four sentences in a specification and the willingness to run one division.
Ask for the average packet size, in bytes, at which the packet rate is measured — the average, not the minimum, because a minimum is what a capability figure is computed from and an average is what the job will send. Ask whether the throughput row is one direction or two, and write the answer beside the number. Ask for the offered load at which the latency figure was taken, and the frame size, in the same cell rather than 400 pages apart. And ask for the buffer as a drain time at the port speed of the model being quoted, because 64 MB means four different things on four different line rates.
The reward for asking is that the arithmetic becomes the buyer's own. Halve the throughput, divide by the packet rate, multiply by eight, and you have the frame the sheet is describing. If it lands on 84 bytes, the number is the worst case and the sheet is telling you what happens when every port streams minimum-size frames — a stress test, honestly labelled by arithmetic. If it lands on 200 bytes, the number is a realistic average and the worst case is roughly 2.4 times higher. If it lands on 333 bytes, the number describes a workload that already exists and the worst case is four times away.
Arista Networks, Inc. is in the BTW directory: arista-networks-inc. Three of its eleven documents will tell you the packet size, and all three bury it under the power figures. The other eight leave a division for the reader, and the division is not hard. It is only unasked.
Member Briefing
Read the full trend briefing
Members read the full briefing with the source notes behind every finding.
Strategic Circle
A daily briefing in your language, built from changes we have verified.
Join for USD 20/monthCancel anytime.
Members also get the full research library, a daily briefing on the networks they follow and the private forum.