Summary

  • A split ratio's ideal cost is exactly a logarithm: every doubling of the count costs 3.01 dB, so 1:32 spends 15.05 dB, 1:64 18.06 and 1:128 21.07 before a metre of fibre is laid. A reach is a multiplication. The budget that both are spent against is a class ceiling, and it is a subtraction.
  • Nokia's 16-port GPON line card prints a 1:128 split, a reach of up to 60 km and three class ceilings on one page as three separate bullets, and qualifies none of them together. Nokia's own technical paper prints the governing inequality and a number for none of the four loss elements it names.
  • Doing the addition with published terms only, a 1:128 split on the 28 dB class leaves 4.6 dB: 18.4 km of feeder at 0.25 dB/km, 13.1 km at 0.35 dB/km, and nothing at all like 60 km. The same split at 60 km on the most favourable pair in the document set exceeds even the 34 dB class by 0.2 dB before a single splice.

Three maxima and a class on one page

The sheet that started this reading is Nokia's ISAM FGLT-D, a 16-port GPON line card for the FX access nodes. On it, in bullets, you get the per-port rates, the split, the reach and the optics: each PON interface delivers 2.5 Gb/s downstream and 1.2 Gb/s upstream and "has a reach of up to 60km (37.3miles)"; the card "Supports 1:128 split; support for 30/60 km (18.6/37.3 miles) reach"; and the pluggable optics are "Class C++ optics (34 dB link loss budget) C+ optics (32 dB link loss budget) and B+ optics (28 dB link loss budget)" (FGLT-D data sheet).

Read those three bullets as a buyer would and you have a card that splits a port 128 ways, reaches 60 kilometres, and holds a link loss of 28, 32 or 34 decibels. Read them as a designer must and you have three maxima printed by one party, none of which is stated to hold at the same time as the other two, and a qualification that is printed nowhere on the page.

The rest of the access-node family is thinner still. The Lightspan FX ANSI data sheet gives shelves, slots and 2 x 100 Gb/s per slot and no optical operand at all (Lightspan FX ANSI data sheet). The MF-14 sheet gives a 15 RU shelf, 16-port cards for four PON generations, 2 Tb/s of switching and a 200 Gb/s uplink, and likewise no decibel (Lightspan MF-14 data sheet). The multi-PON LWLT-C card says it all in one clause: "pluggable optics supporting various ODN link budgets, reach and temperature grades" (LWLT-C card data sheet). The XGS-PON card FWLT-B goes one step further and puts the four XGS-PON classes on the bullet: "pluggable N1, N2, E1, E2 optics, allowing 29dB, 31dB, 33dB resp. 35 dB optical loss budget" (FWLT-B data sheet).

Five Nokia-attributed surfaces, then, and between them a split ratio, a reach, six class ceilings and a per-port line rate. Of the URLs in this reading, only three are nokia.com assets: two of the platform data sheets and the optical-budget paper discussed below. The FGLT-D sheet sits on an Alcatel-Lucent Enterprise host, the FWLT-B and LWLT-C sheets are mirrors, and the table that finally prints a Nokia card's launch power is a reseller's re-typed page.

A count is a logarithm

A passive splitter divides optical power, so its ideal loss in decibels is ten times the base-10 logarithm of the port count. This is my arithmetic, and it is exact: 10·log10(2) = 3.01 dB per doubling; 10·log10(32) = 15.05 dB; 10·log10(64) = 18.06 dB; 10·log10(128) = 21.07 dB.

Three of those figures are the whole economic argument for moving a PON from 1:32 to 1:128. You double the subscribers on a port twice, and the ideal cost is 6.02 dB. Now put the real hardware beside the logarithm, because the difference is not rounding.

TELHUA prints a maximum insertion loss of 16.8 dB at 1x32, 20.5 at 1x64 and 23.4 at 1x128, and in the row beneath it prints the loss uniformity of the same parts: 1.5, 2.0 and 2.5 dB (TELHUA PLC splitter family). Precision OT prints 16.5, 20.5 and 23.8 with uniformity of 1.5, 2.0 and 2.5 (Precision OT splitter datasheet). Montclair prints typical and maximum separately, which is the most honest form on offer: 16.6 and 17.2 at 1x32, 20.1 and 21.5 at 1x64, 24.5 and 25.5 at 1x128, with maximum uniformity of 1.5, 2.0 and 2.6 dB (Montclair splitter datasheet). DMSI's connectorized table gives 17.2, 20.8 and 24.0, or 17.0, 20.4 and 23.7 in its P-grade, with uniformity of 1.5, 2.0 and 2.0 (DMSI splitter specification). Westell prints both ends of the connector question in the same row - 16.5 and 17.0 at 1x32, 20.5 and 21.0 at 1x64 - with channel uniformity of 1.5 and 1.8 dB (Westell OSP-H cassette splitters).

Set the printed maxima against the logarithm and the excess is 2.33 dB at 1x128 on the most optimistic sheet, 2.93 on DMSI's connectorized part and 4.43 on Montclair's maximum. That excess is 11 to 21 per cent of the ideal loss itself. It is not a rounding error, and it is not a constant you can carry in your head: it depends on which vendor's part you bought.

Then there is the uniformity, which is the number that decides the design. A splitter's insertion loss describes the part; its uniformity describes the spread across ports, and a link is designed at its worst port because that is the port a customer is on. Five datasheets print insertion loss and uniformity side by side for the same ratios, which means the worst-port case is a published number and there is no excuse for designing to the average. What none of the five says is whether the printed maximum already contains the uniformity or is spent on top of it.

Montclair's 1x128 maximum of 25.5 dB plus its own 2.6 dB of uniformity is 28.1 dB: the entire B+ class, before a metre of feeder.

The connector question is the same kind of question, and Westell's table answers it in a form worth reading twice. The with-connector minus without-connector difference is exactly 0.5 dB from 1x8 through 1x64 - a printed allowance for the connectorized assembly, not a per-connector figure. TELHUA takes the other convention and says the specifications exclude connectors and "with connectors should add 0.3dB". One number is an assembly allowance, the other a per-connector addition, and they are not interchangeable.

A kilometre is a multiplication

Fibre is the only term in the budget that is a product rather than a count, and it is the term on which published tables disagree most.

ITU-T G.652 gives cable attenuation maxima of 0.4 dB/km at 1310 nm, 0.35 at 1550 and 0.4 at 1625, and separately gives representative concatenated-link values of 0.5 dB/km over 1260 to 1360 nm and 0.275 dB/km over 1530 to 1565 nm (ITU-T G.652). Corning's SMF-28 Ultra datasheet - the same fibre, one product family - prints maxima of 0.32 dB/km at 1310, 0.21 at 1490, 0.18 at 1550 and 0.20 at 1625 (Corning SMF-28 Ultra). The Fiber Optic Association's installation reference uses 0.4 dB/km at 1310 and 0.25 at 1550 (FOA installation deliverables). DIMI's ODN guide uses 0.35 and 0.25 and budgets the splitter at 17.1 dB for 1:32 and 20.5 for 1:64 (DIMI FTTH ODN guide). ANFKOM uses 0.35 at 1310 and 0.2 to 0.25 at 1490 and 1550, and prints a full splitter table with uniformity by ratio - 1:32 maximum 16.5 to 17.1 dB with 1.5 dB uniformity, 1:64 20.5 to 21.2 with 2.0, 1:128 24.2 to 24.8 with 2.5 (ANFKOM FTTH ODN guide). FOI-S-005 uses 0.36 and 0.25 (FOI-S-005 ODN design standard). H3C's white paper uses 0.35 dB/km for G.652D at 1310 nm (H3C GPON and XG(S)-PON white paper).

And then an operator answers. The SCTE21 technical paper authored by Cox Communications prints deployed design parameters by wavelength rather than datasheet maxima: 0.28 dB/km at 1490 nm downstream GPON, 0.34 at 1310 nm upstream GPON, 0.25 at 1577 nm downstream XGS-PON, 0.35 at 1270 nm upstream XGS-PON, a 2.0 dB maximum drop loss for drops under 500 ft, and 1 to 2 dB of margin left for field variables including splice and connector loss (Cox Communications, SCTE21 paper on distributed optical taps).

The spread between those tables is not academic. Twenty kilometres costs 7.0 dB at 0.35 dB/km and 5.0 dB at 0.25 dB/km. Sixty kilometres costs 15.0 dB at 0.25 and 21.0 dB at 0.35. A 20 km link is therefore a 2 dB link, or not, depending on whose attenuation table you picked up - and 2 dB is a whole margin convention.

The class closes, but only with the penalty

Here is the part that makes the ceiling more than a marketing number. ITU-T G.984.2 gives the B+ class the following operands: OLT mean launched power 1.5 to 5 dBm, OLT minimum sensitivity minus 28 dBm, ONU mean launched power 0.5 to 5 dBm, ONU minimum sensitivity minus 27 dBm, both overloads at minus 8 dBm, and a maximum optical loss of 28 dB with a minimum of 13 dB at both 1490 and 1310 nm (ITU-T G.984.2). The same table prints a downstream and upstream optical penalty of 0.5 dB for B+.

My subtraction: a 1.5 dBm launch against a minus 27 dBm sensitivity is 28.5 dB downstream, and a 0.5 dBm launch against minus 28 dBm is 28.5 dB upstream. Subtract the printed 0.5 dB penalty and each lands on 28.0 dB, which is the printed ceiling. The class is not arbitrary and it is not a surprise. It is launch minus sensitivity minus penalty, printed by the standard, in both directions, closing to the decibel.

Now read the reseller's board table for the GPON C+ module, which is the only page in this reading that prints a Nokia card's per-direction optics: transmit 3.00 dBm minimum and 7.00 dBm maximum, maximum receiver sensitivity -32.00 dBm, overload -12.0 dBm, 1490 nm transmit, 1310 nm receive, 2.488 Gbit/s and 1.244 Gbit/s, 16 ports, and a reach of 30 km/60 km (FGLT-B board table). Subtract as the standard subtracts: a 3.00 dBm launch against a minus 32.00 dBm sensitivity is 35.0 dB. The C+ class is 32 dB, printed by Nokia's own line-card sheet and by TEC and H3C. Three decibels are unaccounted for on the page that prints both operands, and no page in the set says which three they are.

The manufacturer prints the inequality

Nokia's own technical paper, "Optical power budgets in PON", is the document this article was looking for, and it delivers the opposite of a worked example. It prints the budget as an inequality: the sum of all losses plus a maintenance margin must be less than or equal to the minimum transmit power minus the minimum receive power minus the optical power penalty (Nokia, Optical power budgets in PON). It puts the optical power penalty "in the order of 1 or 2 dB". It tabulates every class ceiling as a minimum and a maximum - B+ 13 and 28 dB, C+ 17 and 32, D 20 and 35, N1 14 and 29, N2 16 and 31, E1 18 and 33, E2 20 and 35. And it names the terms of the left-hand side: fibre, splicers and connectors, splitters, filter and coexistence. It prints a number for none of them.

That is the finding in its sharpest form. The manufacturer that puts a 1:128 split, a 60 km reach and a 28/32/34 dB ceiling on one line-card sheet publishes, elsewhere, the exact constraint that governs all three - and leaves every operand of that constraint to documents written by other people. The schematic in the paper is a signal-level diagram, not an addition. There is no worked sum, no qualified split-and-reach pair, no table of terms.

The pages that do perform the addition

They exist, and not one of them is Nokia's.

H3C's white paper puts transmit power, receive sensitivity, overload and maximum and minimum allowed loss in one grid across six classes, and then shows its working: 10 km x 0.35 dB/km plus a 20 dB splitter plus 1 dB equals 24.5 dB, with an "e.g., 3dB" margin shown beside it. It also prints a splitter insertion-loss table running from 1:2 at 3.3-4.0 dB to 1:64 at 19.0-21.0 dB, "including 0.3-2 dB device additional loss", and about 0.1 dB per hot junction.

That page is worth reading as a model - and worth reading critically, because its splitter table already contains 0.3 to 2 dB of device additional loss while its own worked example then adds 1 dB of additional loss again, and because its receive column is labelled "Maximum receive sensitivity" where the standard calls the same numbers minimums.

The two vendor ODN guides go further. DIMI prints the complete allowance set - fibre, splice, connector pair, splitter by ratio, and "Design margin (aging, repairs, temperature) | 3.0 dB" - and works a GPON Class B+ example to 26.35 dB with a 1:32 splitter. ANFKOM prints the same categories and reaches 25.00 dB with 1:32 at 8 km against the 28 dB class.

FOI-S-005 does the thing neither does: it requires a lifetime margin of at least 2.5 dB and says it must not be consumed at design time, adds a 0.05 dB/km repair allowance, takes splitter and filter losses at vendor maximum, and instructs the designer to check the farthest ONT against the class limit and the nearest against receiver overload.

And one reseller blog performs the full addition for a Nokia XGS-PON card: a 1:64 splitter at about 20.5 dB, 20 km at 0.25 dB/km for 5.0 dB, splices and connectors at about 2.0 dB lumped, total 27.5 dB, 1.5 dB left against 29 dB (XPONSHOP on the Nokia N2 optic). It is the only page in the set that adds the terms for a Nokia model, and it is a reseller blog - and its own class table contradicts the vendor's, giving N2 a 29 dB ceiling where Nokia's card sheet, TEC and H3C all print 31, and N1 a 24 dB ceiling where they print 29.

What 4.6 decibels buys

Take Nokia's own sheet at its word and spend it. The B+ ceiling printed on that sheet is 28 dB. TELHUA's 1x128 maximum insertion loss is 23.4 dB. Both operands are printed; the subtraction is mine: 28 - 23.4 = 4.6 dB, and that is every decibel left for feeder, splices, connectors and margin on a 1:128 split in the lowest class the same page offers.

At 0.25 dB/km those 4.6 dB buy 18.4 km of feeder with nothing else spent. At 0.35 dB/km they buy 13.1 km. Sixty kilometres of feeder, the reach printed one bullet above, costs 15.0 dB at 0.25 and 21.0 at 0.35: the 1:128 split on B+ is short of the sheet's own reach by 10.4 dB and 16.4 dB respectively.

Move to the top of the page and it still does not close. A 1:128 split at 60 km on the most favourable pair in the entire document set - TELHUA's 23.4 dB and Corning's 0.18 dB/km at 1550 nm - is 10.8 plus 23.4 = 34.2 dB. The C++ ceiling printed on the same Nokia sheet is 34 dB. The combination exceeds it by 0.2 dB before a single splice, a single connector or a single decibel of margin.

Add the ordinary furniture and the answer moves further. A 1:128 design at 20 km, carrying a splitter at 23.4 dB, 20 km of feeder at 6.4 dB, four fusion splices at 0.40 dB, four mated connector pairs at 1.20 dB and a 3.0 dB margin, totals 34.4 dB. That is above C+ at 32 dB, above C++ at 34, and closes only on the 35 dB class that Nokia's paper lists as D and E2.

What the same arithmetic does to a plain 1:32 design

None of which is an argument against splitting. It is an argument about which number binds.

A 1:32 design at 20 km, with the same four splices, four connector pairs and a 3.0 dB margin, comes to 27.8 dB on Corning's 0.32 dB/km at 1310 nm and 28.4 dB on the 0.35 dB/km cable maximum that G.652, FOA and DIMI all use. One design, two published fibre tables, 0.6 dB apart - and 0.6 dB is the difference between inside Class B+ and outside it.

Swap the connector convention and the gap widens. The layer-spec calculator reports ANSI/TIA-568.3-E's maxima of 0.75 dB per standard-grade mated connector pair, 0.30 dB per fusion or mechanical splice, and 0.50 dB reference-grade to standard-grade, alongside OS2 cable at 0.4 dB/km at both 1310 and 1550 nm and the observation that G.652's Appendix I requires a margin without giving a figure (layer-spec fibre loss calculator). Four pairs at 0.75 dB is 3.00 dB instead of 1.20, and the same design goes to 29.6 dB on the lower fibre figure and 30.2 on the higher: 1.6 and 2.2 dB over the class.

Run it the other way and ask what a designer actually controls. Hold the splitter at 16.8 dB, the splices at 0.40, the connectors at 1.20 and the margin at 3.0, and the headroom left inside 28 dB for feeder is 6.6 dB. That buys 18.9 km at 0.35 dB/km and 20.6 km at 0.32 dB/km - the answer straddles exactly the 20 km that the TEC XGS-PON requirement makes mandatory (TEC Generic Requirements: XGS-PON). Anything longer is a smaller split, a higher class, a tighter connector budget or no margin.

Which sixty kilometres

The standard prints two reaches in one table and they are not the same quantity: a maximum logical reach of 60 km and a maximum fibre distance of 20 km, with 10 km as an option. TEC restates the pair in its own units - at least 20 km of fibre distance, 60 km of logical reach at the transmission-convergence layer, 40 km of differential distance. Nokia prints "up to 60km" and does not say which one it means. Nothing in the set resolves it, and the difference between the two is three times the distance.

The same paper prints the other half of the split question. TEC makes 1:64 the minimum requirement for XGS-PON, subject to the overall loss budget, allows 1:128 with different class optics and 1:256 as optional. ITU-T G.984.2 prints the split only as "Restricted by path loss PON with passive splitters (16, 32 or 64 way split)" - a 1:64 ceiling in a standard where the vendor sheet offers 1:128. So the qualification a buyer wants is printed, by a regulator and a standard, in a form that makes the vendor's bullet a starting point rather than an answer.

Where the printed specification stops

TEC also does something no other page does: it names a component loss and then says which loss it leaves out. Its WDM1r insertion loss is printed as 0.8, 1.3, 1.4 and 1.6 dB, with a note that connector loss is excluded. That one sentence is the discipline the rest of the set lacks. Splitter datasheets print insertion loss and uniformity and do not say whether one contains the other. Vendor guides print a margin and do not say whether it is additive to the class or already inside it. The standard requires a margin for future splices, extra cable, ageing and temperature and prints no number for it.

The disagreement is not a scandal and it is not a mystery. It is what happens when five terms of one subtraction are published by five different parties: a fibre maker, a splitter maker, a connector catalogue, a splice standard, an operator's design guide and a vendor's inequalities, each truthful about its own term and none of them owning the sum.

The countercase, stated plainly

Six things in this reading argue against the strongest version of that complaint, and they should be printed.

First, the manufacturer does print the governing equation, and it prints every class ceiling. What it withholds is a number for any of the four loss elements it names.

Second, splitter uniformity is not a missing term. Five datasheets print it beside insertion loss for the same ratio in the same table, so the worst port is a published number and any reader can design to it.

Third, the class really closes when the printed penalty is included: 28.5 minus 0.5 is 28 in both directions. The ceiling is not arbitrary, and the vendor that omits the operands is not concealing an unexplainable number.

Fourth, the split-to-reach qualification is printed - by a regulator, not by the vendor. TEC's 1:64 minimum, its conditional 1:128 and its 20 km fibre distance are an answer, just not the vendor's.

Fifth, worked additions exist. H3C reaches 24.5 dB with a margin shown beside it, DIMI reaches 26.35, ANFKOM reaches 25.00, and the reseller blog reaches 27.5 against 29.

Sixth, an operator's own numbers exist and are better than the manufacturer's: Cox prints deployed attenuation at all four wavelengths a PON actually uses and states how much margin it left.

What no page does is the thing the buyer needs: add the split, the reach, the splices, the connectors and the margin for one Nokia model at one named class, and show the result against that class ceiling.

What this reading does not say

Every absence here is a count over the 26 documents named at the end of this article, read on 26 November 2026. It is not a claim about what Nokia publishes anywhere else, and several documents were read as provider extractions of PDFs rather than opened page by page, so an absent term is absent from the extracted text first of all. Several hosts are mirrors or resellers carrying Nokia-attributed content, and they are named as such where their figures are used.

Nothing here says a printed combination is unbuildable. A vendor's maxima are permissions, not measurements, and a link is designed against limits rather than averages. A class ceiling is the ceiling of a named optical class, not a rating of any particular system. Every derived figure above is my arithmetic, with both operands printed on the page that prints them, and no quotient is taken across two wavelengths, two directions, two classes or two editions unless a reviewed page says both operands describe the same thing. Where suppliers disagree, both values are printed with their hosts and neither is adopted.

Two questions stay open and change the answer. Whether a printed splitter maximum already includes its port-to-port uniformity is unstated by all five datasheets, and on Montclair's 1x128 part the difference is 25.5 dB against 28.1 dB. Which of the standard's two 60 km figures the line-card sheet means is likewise unstated, and the difference is a factor of three. A third belongs beside them: whether the three unexplained decibels between the reseller C+ table's 35 dB subtraction and the 32 dB class are penalty, margin, a different measurement point, or an error.

Sources