Summary

  • The efficiency class is defined at 25 °C ambient, at a rating for altitudes up to 1,000 m, at rated output on 50 Hz; the regulation that requires it exempts only motors specified exclusively for altitudes above 4,000 m or ambient above 60 °C, so an obligation runs across a corridor the measurement never entered.
  • Siemens fills that corridor with a printed multiplier on power alone — 1.07 at 1,000 m below 30 °C down to 0.63 at 4,000 m and 60 °C — and one sentence admitting that efficiency and power factor will also be less favourable, with no figure in any cell of the table.
  • Thirteen documents read on 26 November 2026 print no efficiency for any derating cell, no statement of which exemption a motor line relies on, and no converter-fed efficiency percentage for a named motor; the class is correct where it is measured, and that is the whole of the finding.

The stamp and the table

A class is a short word doing a long job. On the nameplate of a SIMOTICS machine it sits in item 40, beside item 41, which carries the efficiency percentage, and item 4, which carries the standards (SIMOTICS SD operating instructions). Three fields, not one: the class you bought, the number you were quoted, and the document that says how the number was obtained. The same operating instructions list EN/IEC 60034-2-1 for determining losses and efficiency, and EN/IEC 60034-2-3 for converter-fed machines, in one standards table.

What the class means is written elsewhere, and it is written as a condition. Annex I of Commission Regulation (EU) 2019/1781 says it in one sentence:

IE classes are determined at rated output power (PN), rated voltage (UN), based on the 50 Hz operation and 25 °C ambient reference temperature.

That sentence is on the adopted Annexes page (Regulation (EU) 2019/1781, Annex I). The standard the class is named after repeats the condition in its notes — rated efficiency and efficiency classes based on a 25 °C ambient temperature in accordance with IEC 60034-2-1, and on a rating for altitudes up to 1,000 m above sea level (IEC 60034-30-1:2025). Two instruments, one perimeter, and the perimeter is a room at 25 °C at the bottom of a valley.

It gets more specific than that. The same page of Annex I counts the class step in percentages. Table 2, minimum efficiencies for IE3 at 50 Hz, row 18,5, reads 92,4 / 92,6 / 91,7 / 90,1 across two, four, six and eight poles; Table 3 reads 93,7 / 94,2 / 93,4 / 91,7. At 18.5 kW and four poles, the regulation's own printed values are IE3 92,6 % and IE4 94,2 %, in the official English text's decimal-comma convention (Annex I). Those two numbers are the whole arithmetic currency of this article, and neither of them is a measurement of a motor in a hot room.

Three perimeters, one label

The obligation and the measurement part company at the edges of a table, and the regulation's scope article says exactly where. Article 2(1)(a) reaches induction motors without brushes, commutators, slip rings or rotor connections, rated for 50, 60 or 50/60 Hz sinusoidal voltage, with two, four, six or eight poles, above 50 V up to 1,000 V, from 0,12 kW up to 1,000 kW, rated for continuous duty and for direct on-line operation (consolidated text 02019R1781). Then Article 2(2) turns the requirements off for fifteen lettered classes of motor, opening with:

The requirements in section 1, and points (1), (2), (5) to (11), and (13) of section 2 of Annex I shall not apply to the following motors:

and running to (o). Point (c) is the narrow brake carve-out: motors with an integrated brake forming an integral part of the inner motor construction, one that can neither be removed nor powered by a separate power source while efficiency is being tested. The tail is multi-speed motors, described as motors with multiple windings or a switchable winding giving a different number of poles and speeds, and motors designed specifically for the traction of electric vehicles (EUR-Lex).

Point (d) is the one that matters here, and it is worth reading in full because its grammar is the finding:

motors specifically designed and specified to operate exclusively: (i) at altitudes exceeding 4 000 metres above sea-level; (ii) where ambient air temperatures exceed 60 °C; (iii) in maximum operating temperature above 400 °C; (iv) where ambient air temperatures are less than – 30 °C; or (v) where the water coolant temperature at the inlet to a product is below 0 °C or above 32 °C;

The subject of that sentence is the specification, not the installation. A motor specified exclusively for thin air is out; a motor sitting at 3,500 metres that was ordered off a catalogue page is in, and its class still has to be at least IE3. That is not a loophole anybody needs to exploit, because the seller has already provided the ladder that fills the gap — which is the second perimeter.

Siemens' own selection procedure steps at 40 °C ambient and 1,000 metres of installation altitude, and its derating section states the baseline plainly: the catalogue power applies at 50 Hz, at 40 °C coolant and ambient temperature, and at altitudes up to 1,000 m. Above those limits, the specified motor power must be reduced using the factor kHT, with Padm = Prated × kHT (Catalog D 81.1 Add-on, 03/2018). So there are three numbers, and they are three different numbers. Twenty-five degrees and 1,000 metres is where the class is measured. Forty degrees and 1,000 metres is where the seller's published power is true at 1.00. Sixty degrees and 4,000 metres is where the regulation stops asking.

The corridor between the first and the third is 35 kelvin wide and 3,000 metres deep — 60 minus 25, and 4,000 minus 1,000 — and it is not a rhetorical gap. It is the place where the obligation still bites and the label was never tested.

What the seller multiplies

The derating table is titled, in the document actually read, 'Reduction factor kHT for different installation altitudes and/or coolant temperatures', and it is a ladder rather than a formula. Rows run from 1,000 to 4,000 m; columns run across coolant temperature in bands of <30, 30-40, 45, 50, 55 and 60 °C, rounded to 5 °C and 500 m respectively (Add-on 03/2018). The printed cells read:

  • at 1,000 m: 1.07, 1.00, 0.96, 0.92, 0.87, 0.82;
  • at 1,500 m: 1.04, 0.97, 0.93, 0.89, 0.84, 0.79;
  • at 2,000 m: 1.00, 0.94, 0.90, 0.86, 0.82, 0.77;
  • at 2,500 m: 0.96, 0.90, 0.86, 0.83, 0.78, 0.74;
  • at 3,000 m: 0.92, 0.86, 0.82, 0.79, 0.75, 0.70;
  • at 3,500 m: 0.88, 0.82, 0.79, 0.75, 0.71, 0.67;
  • at 4,000 m: 0.82, 0.77, 0.74, 0.71, 0.67, 0.63.

Every cell is a permission to keep selling the same frame with a smaller number printed beside it. Take the corner. At 4,000 m and 60 °C the factor is 0.63, so an 18.5 kW nameplate delivers 11.655 kW there — 37.0 per cent less, my multiplication, both operands named. Inverted, a site that genuinely needs 18.5 kW of shaft power at that corner must order 18.5 ÷ 0.63 = 29.37 kW of nameplate, 58.7 per cent more machine than the load requires, my division, and the larger machine carries a different class value than the 92,6 % printed at 18.5 kW, which no page read here converts back into a site figure.

That inversion is the buyer's real invoice, and it is the reason the missing efficiency number is not a pedant's complaint. He is not being sold 18.5 kW at 4,000 metres. He is being sold 29.37 kW at sea level and told a factor will reconcile the two.

The efficiency sentence

Here is the whole of what the derating block says about the quantity the class names:

In the case of extreme derating, the operating data for the motors, i.e. efficiency and power factor, will also be less favorable due to partial utilization.

One sentence, in the same section, and it is honest. It does not claim the efficiency holds. It says the operating data — efficiency, and power factor as well — become less favourable because the machine is only partly utilised. What it does not do, anywhere in the block, is print the efficiency for any cell, or add a second table of efficiencies alongside the factors. The kHT matrix quantifies power to two decimals in twenty-eight cells and quantifies efficiency in none (Add-on 03/2018).

The same block also tells the buyer how far he has strayed from the catalogue: motors for coolant temperatures other than 40 °C, or for altitudes above 1,000 m, in temperature class 130 (B), must be ordered with the '-Z' order code and plain text. So the corridor has an order path. What the corridor does not have, in any document read for this piece, is a percentage.

Twenty-five degrees is not a rung

Read the columns again and something worse appears. The label's own reference temperature, 25 °C, is not a rung on the ladder. It falls inside the '<30 °C' band, and at 1,000 m that band prints 1.07 — a credit above nameplate. So the same frame, at the temperature where the regulation defines its class, is credited with 18.5 × 1.07 = 19.795 kW, 7.0 per cent above the number on its own nameplate, my multiplication (Add-on 03/2018).

The seller's declared baseline, 40 °C at 1,000 m, is 15 kelvin above the standard's reference temperature, and it is exactly the rung where the factor is 1.00. The catalogue has therefore chosen the point at which its power equals its nameplate as a point 15 K hotter than the point at which its efficiency equals its class. Both choices are defensible. They are not the same choice, and nothing in the table says so.

What a class step is worth

The reason all this matters in money rather than in metrology is that the step between classes is narrow. At 18.5 kW and four poles the printed values are 92,6 % and 94,2 %, a difference of 1.6 percentage points, and points are a poor way to feel it. Convert both to losses as a fraction of output, which is my arithmetic and named as such: IE3 loses 0.074 ÷ 0.926 = 0.0799136 of its output, IE4 loses 0.058 ÷ 0.942 = 0.0615711. The ratio is 1.29792, so the IE3 machine dissipates 29.8 per cent more heat for the same shaft power. In watts, input is 18.5 ÷ 0.926 = 19.978 kW against 18.5 ÷ 0.942 = 19.639 kW: losses of 1.478 kW against 1.139 kW, a gap of 0.339 kW (Annex I).

Multiply that gap by hours and it becomes a fuel bill. At 8,000 running hours a year — the hours figure is my assumption, not a printed one — 0.339 kW × 8,000 h = 2,712 kWh saved per motor per year by the class step, my multiplication. A plant with two hundred such motors is being invited to think in gigawatt-hours, which is precisely why the class exists as a regulatory instrument.

Which is also why a tolerance nearly as wide as the step is worth staring at.

The tolerance beneath the stamp

The IEC class value is a floor, and a second instrument puts a tolerance under it. IEC 60034-1 Table 20, known here through an EASA engineer's trade article rather than read directly, permits an efficiency tolerance of −15 per cent of (1 − η) for motors up to 150 kW and −10 per cent above (EC&M, 12 June 2013). At 92,6 % that is 0.926 − 0.15 × 0.074 = 91.49 %, a shortfall of 1.11 points, my arithmetic, which is 69.4 per cent of the whole 1.6-point step from IE3 to IE4.

The North American construction is blunter still, and it works in the other direction. NEMA's own account of MG 1 says the nameplate nominal is chosen from Table 12-10 and is not greater than the average efficiency of a large population of the same design, while an individual motor need only meet the minimum value associated with its nominal in the same table (NEMA, Motor Standards vs IEC Motor Standards). The same slides label that minimum column 'Based on 20% Loss Difference', and print the pairs 95.4 to 94.5 and 98.5 to 98.2. The trade article gives the clause number and the worked example: MG 1 clause 12.58, a nominal of 94.5 % with a minimum of 93.6 %, because the minimum represents 20 % higher losses (EC&M).

Set that beside the class values and the arithmetic is uncomfortable. A nominal of 92,6 % with a permitted 20 per cent higher loss holds a floor of 1 ÷ (1 + 0.0799136 × 1.2) = 91.25 %, which is 1.35 points below the number it is stamped with, my division. As a share of the IE3-to-IE4 step that is 1.35 ÷ 1.6 = 84.4 per cent.

In loss terms instead of points — and the denominator matters, so here is the other one — the step is a factor of 1.29792 in losses, the tolerance is a factor of 1.20, and the tolerance is therefore 0.20 ÷ 0.29792 = 67.1 per cent as wide as the whole step, my division. Two documents, two denominators, two defensible percentages: 84.4 in points, 67.1 in losses. What they agree on is that a motor stamped near the IE3 floor may honestly measure closer to the value the class below it is stamped with than to its own.

The comparison only works if the two vocabularies are kept apart, which is why the numbers above are stated twice. A NEMA nominal is not an IEC class boundary: one is a population average with a floor beneath it, the other is a statutory floor with a tolerance beneath that. The band widths are comparable. The quantities are not.

The row where the load is not four-quarters

Everything above concerns the efficiency at rated load. The catalogue's data tables print three efficiencies per motor, at 4/4, 3/4 and 2/4 load, under column headings reading ηrated, 50 Hz, 4/4, ηrated, 50 Hz, 3/4 and ηrated, 50 Hz, 2/4 (Catalog D 81.1, 09/2023). Two complete rows were readable for this piece, and neither is the current catalogue's own page: a distributor page for one 18.5 kW four-pole IE3 motor, frame 180 M, 1,470 rpm, 120 Nm, 35 A at 400 V, power factor 0.82, 134 kg, which prints 92.6 % at 4/4, 93.1 % at 75 % and 92.9 % at 50 % (OSA Žilina product page); and a 2012 edition's cast-iron row for 18.5 kW at 50 Hz, 21.3 kW at 60 Hz, frame 180 M, 1,470 rpm, 120 Nm, IE3, printing 92.6 / 93.2 / 93.2 (Catalog D 81.1, 2012 edition).

In both rows the 4/4 figure is the lowest of the three and the maximum sits at 3/4 load, by 0.5 points on the aluminium machine (93.1 − 92.6) and by 0.6 points on the cast-iron one (93.2 − 92.6), my subtractions. The shape is what the two rows share; the digits describe different series in different editions, and the current catalogue's own row could not be opened in this session.

Read against the class, the consequence is small and awkward: the number a buyer compares with the statutory floor is the least favourable number printed on the row, and the place where his motor actually runs — a pump or a fan at three-quarters load — is the place where it looks best.

The 60 Hz column that is not there

One more absence, on the same rows. The efficiency columns are headed ηrated, 50 Hz at all three loads. The same row prints a 60 Hz rating of 21.3 kW against 18.5 kW at 50 Hz — 15.1 per cent more power on the same frame, my division (21.3 ÷ 18.5 = 1.15135) — and among the headings read there is no 60 Hz efficiency column at all (Catalog D 81.1, 09/2023, 2012 edition). A buyer taking the 60 Hz rating is taking a power claim from a row whose efficiency was printed at 50 Hz. Whether IEC 60034-30-1's own 60 Hz tables close that gap is a question this reading cannot answer, because the standard's numeric tables sit behind a paywall and were not read.

The drive, and the standard that measures it

The class also stops at the terminals. IEC 60034-30-1 says so in its notes: motor losses due to harmonic content of the supply voltage, losses in cables, filters and frequency converters, are not covered (IEC 60034-30-1:2025). A motor on a variable-frequency drive is therefore outside the quantity its class describes — the most common way a pump or a fan is actually run, and the case the label says nothing about.

A separate standard measures that case. IEC 60034-2-3:2024 determines converter-fed losses and efficiency at seven standardised load points, with interpolation into the constant-flux, field-weakening and overload ranges; its reference conditions are a 'comparable converter', a two-level voltage source converter with a switching frequency not above 5 kHz for motors up to 3,600 rpm, and a reference point of 90 % speed at rated torque in constant flux. It states that converter-fed losses are higher than on a sinusoidal supply, and that the results compare designs rather than predict a drive train (IEC 60034-2-3:2024).

Which makes the absence sharp. The Siemens operating instructions list EN/IEC 60034-2-3 in the applicable-standards table (operating instructions). Among the thirteen documents read on 26 November 2026, not one prints a converter-fed efficiency percentage for a named motor. The test is named. The number is not.

Three fields on one plate

Put the pieces together and the plate is doing more work than it looks. Item 40 carries the class, item 41 the efficiency, item 4 the standards (operating instructions) — and the class is a claim about a condition that the plate does not carry at all. Twenty-five degrees, 1,000 metres, rated output, 50 Hz, sinusoidal supply: five conditions, none of them on the plate, all of them in instruments the buyer is not handed.

The regulation knows this, and its answer is revealing. Annex I section 2 imposes an information duty not on the efficiency but on the perimeter: product information must state the range of operating conditions, including altitudes above sea level, minimum and maximum ambient air temperatures, inlet water coolant temperature, maximum operating temperature and potentially explosive atmospheres — and an exempt motor must state 'the specific reason why it is considered exempt' (Annex I). The perimeter is a mandatory disclosure. The efficiency inside the perimeter is not.

Thirteen documents, three absences

The reading behind this piece is thirteen documents, dated 2012 to 2025 wherever a date is printed, read on 26 November 2026: the regulation's adopted Annex I and its consolidated Article 2, three IEC records, a Siemens add-on, the 09/2023 catalogue, its 04/2024 successor, an operating-instructions PDF, a NEMA deck, a trade article and two distributor or third-party-hosted catalogue rows. Across that set, three absences hold.

First, not one prints an efficiency figure for any cell of the derating table. Second, not one states which of the fifteen Article 2(2) classes, if any, a given motor line relies on. Third, not one prints a converter-fed efficiency percentage for a named motor — though IEC 60034-30-1's own scope does treat motors rated exclusively outside −30 °C to +60 °C as special construction, which is the same 60 °C at which the regulation's exemption begins (IEC 60034-30-1:2025, EUR-Lex).

Those are counts over a named set of documents read on a named date, not claims about what the companies have never published. Two of the four catalogue documents are PDFs that exceeded the retrieval channel, so their body pages were not opened and their derating wording is quoted from the March 2018 add-on; the 09/2023 edition is quoted only where a returned excerpt shows the sentence. IEC 60034-30-1's numeric tables were not read; every class value in this article comes from Annex I of the regulation, which the standard's scope and notes corroborate without restating them numerically.

IEC 60034-1 Table 20 is known through the trade article. NEMA MG 1 Table 12-10 and clause 12.58 are known through a slide deck and that same article, not through MG 1 itself. No price list was read, so this piece asserts no price for a class step and no cost per kilowatt of efficiency.

Who sells the ladder now

The catalogue number has changed hands, which adds a small comedy to the page references. The 04/2024 edition of D 81.1 is published under another imprint and carries the transfer statement: 'The Siemens Businesses Large Drives Applications and Low Voltage Motors have been transferred to Innomotics. The brand change from Siemens to Innomotics is ongoing.' It sends readers to innomotics.com/low-voltage-motors and to the local Innomotics branch (Catalog D 81.1, 04/2024). The transfer is the catalogue's own statement, printed under the document number that carried the ladder, and it announces a change of brand rather than of tables. Nobody's class value moved. The company printing it did.

Meanwhile the 09/2023 edition's drive-selection step prints 'Factors for derating None / Determine the factor for derating (for reduction factor, see "Coolant temperature and installation altitude" on page 1/30)', while the table of contents of the same edition lists that section at 1/31. One of the two printed references is wrong (Catalog D 81.1, 09/2023). The ladder has been printed the same way since at least March 2018, so the document family has had five years to add a column to it and, in anything read here, has not.

The bill the buyer cannot compute

Here is the plainest way to say what the corridor costs. A plant at 3,500 m and 55 °C takes the printed factors: kHT 0.71 at that rung. A load needing 18.5 kW of shaft power must order 18.5 ÷ 0.71 = 26.06 kW of nameplate, my division. The motor arrives stamped at its own output, and its class is correct — measured at 25 °C, at a rating for up to 1,000 m, at rated output.

What the buyer cannot do is take the efficiency percentage he was quoted and convert it to the heat his room will actually receive, because the efficiency at 3,500 m and 55 °C appears in no cell of the table that told him the power. He holds a reference-condition claim, a derated power number, and one sentence promising the first will be worse than it says.

The correct reading of that sentence is not that anybody lied. Every number in the table is right at its own rung, the class value is right at its own condition, and the environment minister who wanted to know why a motor is exempt has been given a duty to be told. The finding is narrower and harder: the label's perimeter is not the obligation's perimeter, the seller's baseline sits between the two, and the only place the missing efficiency is acknowledged is a subordinate clause with no figure in it. A class is a permission, and this one is granted at 25 °C.

IEC has already moved the edge once more. The second edition of IEC 60034-30-1, dated 2025-12, introduces IE5 and states that the class definition is generally independent of the output power to frame size assignment, so a given output may be built a frame size larger to reach a higher class (VDE Verlag preview). The ladder keeps gaining rungs. The column that would tell you what happens in a hot room is still the one nobody prints.