Summary
- The ITU's worked example for a class 4 chain closes exactly at 1,500 nanoseconds at the end application, and 1,100 of those nanoseconds are spent before the last device.
- Its largest single line gives one boundary clock 550 nanoseconds of constant time error, five and a half times the unfiltered error the same family allows a class A clock, and no page in the reviewed set says how many clocks that line assumes.
The International Telecommunication Union does not sell time. It writes down how wrong a network's time is permitted to be, and it writes the permission in four units that never meet: a fractional frequency at the source, a nanosecond error per class of clock, a nanosecond error through a named filter at a named point on the chain, and a microsecond requirement at the application. Anyone buying synchronisation is buying inside that permission. The twelve documents reviewed here never put the four in one sentence together.
The budget that closes
Start with G.8271.1, the recommendation that prints the operative network limit for the only class that has one. Class 4 applications are allowed 1.5 microseconds at reference point E, the end application. Between the source and that point the network may consume 1,100 nanoseconds at reference point C, measured after a first-order 0.1 Hz low-pass filter.
Then the amendment prints a worked example for class A clocks: PRTC and T-GM 100 ns, network dynamic time error 200 ns, T-BC constant time error 550 ns, link asymmetry 250 ns. That is 1,100 ns at C. Two further lines finish the job, 250 ns for end-application rearrangement and 150 ns for end-application noise, and the total at E is 1,500 ns. The addition is mine: 100 + 200 + 550 + 250 = 1,100, and 250 + 150 = 400, so 1,100 + 400 = 1,500. The recommendation prints the line items; nobody prints the sum.
It closes at both points, which is the first surprising thing. A budget that adds up exactly invites the belief that the engineering behind it is equally exact. What the example actually distributes is uncertainty.
One line, eleven clocks
The largest line in that example is 550 ns, and it belongs to one component: the constant time error of a T-BC. Set it beside the same family's own per-clock limits and the shape changes. G.8273.2 states, in its own words, that at the precision time protocol and one pulse per second outputs the maximum absolute time error for a T-BC or T-TSC is unfiltered: 100 ns for class A, 70 ns for class B, 30 ns for class C, and for further study for class D. Its constant-error range is plus or minus 50 ns for class A, plus or minus 20 ns for class B, plus or minus 10 ns for class C.
So the example gives a single component of the chain 5.5 times the total unfiltered error a class A clock is allowed, and 11 times that clock's constant-error allowance. Both quotients are mine: 550 / 100 = 5.5 and 550 / 50 = 11. This joins an example allocation to a normative limit rather than exposing a contradiction inside one table, and the example is printed as an example, not as a universal split between transport, access and equipment.
But it does tell you what 550 ns is not. It is not one clock's budget. It is the budget for however many boundary clocks the chain contains, and the reviewed set never states the count anywhere. Put a number on it with my own arithmetic and it is eleven class A clocks at 50 ns each, or 18.3 class C clocks at 30 ns each. Nanoseconds do not record how they were assembled.
Two filters, one box
The filters are where the two halves of this argument stop being comparable. The network limit at C is stated on filtered time error, max|TEL|, while the box at the end of the chain is certified on unfiltered max|TE|. The dynamic part of the network budget arrives as an MTIE mask: 100 + 75 tau ns from 1.3 to 2.4 seconds, 277 + 1.1 tau ns from 2.4 to 275 seconds, and a flat 580 ns from 275 to 10,000 seconds. High-frequency dynamic error at C is capped at 200 ns peak to peak over a 10,000 second interval, measured after a 0.1 Hz high-pass filter.
One numeral does a lot of travelling here. The figure 100 ns appears in this set as the PRTC and T-GM line of the example, as the unfiltered max|TE| of a class A boundary clock, and as the time output of a PRTC-A against Coordinated Universal Time. Three objects, three measurement bases, one digit. That observation is mine; the three figures are printed.
The class with no comparable number
The tightest class does not print the comparable number at all. Class D's 5 ns is max|TEL| after a 0.1 Hz low-pass filter, and its unfiltered max|TE| is still for further study. Read the class table in G.8271: class 3 is 5 microseconds, class 4 is 1.5 microseconds, class 5 is 1 microsecond, class 6 is x nanoseconds, all measured at E. Then read clause 7.3.1 of G.8271.1, which defines the regular reference-point-C limits for class 4 and leaves the other classes for further study.
So the tighter the application requirement, the less printed network budget exists to serve it. That inference is mine, joining one table to one clause. G.8271 supplies the frame, the letters A to E: A is the PRTC output, B the packet master output, C the packet slave input, D the packet slave output, E the end application. The network between B and C may itself be split into a transport part and an access part with separate budgets.
The floor is 1997
Underneath all of it sits G.811, in force since September 1997 with an April 2016 amendment: the maximum allowable fractional frequency offset for observation times greater than one week is 1 part in 10 to the eleventh, over all applicable operational conditions.
Convert that into the units of the budget and the two halves of the specification pull apart. A week is 604,800 seconds; at 1 part in 10 to the eleventh it accumulates 6,048 nanoseconds. Mine. Set against the 1,500 ns end-application allowance, the floor alone exceeds the entire budget by a factor of 4.03 over the interval the floor itself names. Mine. The longest nanosecond window printed anywhere in the reviewed set is 10,000 seconds, at the end of the MTIE mask and in the high-frequency dynamic measurement; one week is 60.48 times that window. Mine, and joined across two documents.
Above the floor, G.8272 gives a PRTC-A 100 ns or better against the applicable UTC source under normal locked conditions, and a PRTC-B 40 ns or better, measured for the combined clock and generator through a moving average of at least 100 consecutive samples. There is no separate constant-error requirement, the values already include offset, wander and jitter, and integrating a time generator with the clock earns no extra allowance. A frequency offset against an averaging interval and a time error against UTC are different instruments. No reviewed page converts one into the other.
The profile is not the promise
The protocol profiles are the part a network engineer actually configures, and they promise least. G.8275.1 is the full-timing-support profile: IEEE 1588, default domain 24 in a range of 24 to 43, multicast messages with unicast not permitted in this version, and Ethernet, OTN, MTN or FlexE transport with at least one required. G.8275.2 is the partial-timing-support companion: unicast over UDP/IP, IPv6 required and IPv4 permitted, default domain 44 in a range of 44 to 63. G.8275.1 says of itself that it specifies interoperability and configuration and does not by itself guarantee that an application requirement will be met.
The catalogue pages carry status rather than limits: G.8271 at 03/20 with Amendment 1 (08/24), G.8273.2 at 06/23 with Amendments 1 (08/24) and 2 (11/25), G.811 at 09/97 with Amendment 1 (04/16), G.8272 at 07/25 with Amendment 1 (08/26) prepublished, and G.8275.1 at 02/26 with Amendment 1 (08/26).
What the twelve documents do not print
No holdover. None of the reviewed documents prints how long a clock or a network must keep usable time once the reference disappears. Every value in the set is a limit, an objective or an allowance; none is a measured error from a deployed chain. And the reading has a grade: all twelve arrived as text returned by a retrieval adapter, no page was opened end to end in a browser, the G.8273.2 table is fragmentary, the lower bound of one MTIE interval arrives as the letter m where a number belongs, and the August 2026 amendments to both protocol profiles were listed in force and not inspected.
Every absence above is a count over these twelve documents read on 25 November 2026, not a claim about what the ITU publishes anywhere.
What a buyer can check
A buyer of synchronisation cannot verify any of these numbers directly. The useful questions are not how accurate the clock is but at which reference point the promise is measured, through which filter, over which interval, across how many clocks, and what the promise becomes when the reference goes away. The reviewed set answers the first three for exactly one class and the fourth only by allocating a number to a quantity of clocks it does not count. The fifth it does not answer at all.
That is the shape of a specification written for equipment tested at a port and deployed across a network. The gap between the port and the network is where the money is spent, and it is the one place the paperwork leaves blank.
Member Briefing
Read the full trend briefing
Members read the full briefing with the source notes behind every finding.
Strategic Circle
A daily briefing in your language, built from changes we have verified.
Join for USD 20/monthCancel anytime.
Members also get the full research library, a daily briefing on the networks they follow and the private forum.