Summary
- Cisco's own Power over Ethernet guide lists class 8 at 90 W as "the maximum power required from the device"; the IEEE 802 tutorial and Microchip's 802.3bt white paper put the device-side permission for the same class at 71.3 W, and the 18.7 W between them is the allowance for a 100 m cable that nobody measures on site.
- The budget that decides how many ports actually get powered sits in footnote one, not the headline: 21 of 48 ports at 90 W on a Catalyst 9300, 260 of 384 on a C9410R, 226 on a Catalyst 9400 line-card sheet. The 9200 data sheet is the one page that performs the multiplication itself — "24 PoE+ 30W ports = 720W" — against a 370 W single-supply budget.
- On the modular chassis the budget is not a number but a formula in three choices the buyer makes: how many supplies, at what site voltage, in which redundancy mode. Four supplies in a C9404R yield 6,390 W in N+N at 230 V and 3,130 W at 115 V — my arithmetic on Cisco's printed formula, and a factor of 2.04.
- When requests exceed the budget the switch denies power, switches the port off, writes a syslog line, updates an LED and retries periodically. A static port reserves its configured maximum with nothing plugged in, and static ports are served before the auto ports.
One cable, three watts
A ceiling above a floor of desks carries one cable per device, and the cable carries both the data and the power. That is the arrangement Power over Ethernet bought: no mains socket at the access point, no electrician in the ceiling, one run of copper doing two jobs. The arithmetic that makes it safe is written by one standard, and the standard prints three numbers for every power class — what the switch port must be able to supply, what the device at the far end is permitted to draw, and the difference, which is what the cable is allowed to spend.
The Cisco Catalyst 9000 Power over Ethernet configuration guide gives the classes as a table of maximum power: class 0 at 15.4 W, class 1 at 4 W, class 2 at 7 W, class 3 at 15.4 W, class 4 at 30 W, class 5 at 45 W, class 6 at 60 W, class 7 at 75 W and class 8 at 90 W, and it describes those as the maximum power required from the device (PoE configuration guide, Catalyst 9000). The same page maps the types: PoE at 802.3af Type 1 is 15.4 W, PoE+ at 802.3at Type 2 is 30 W, PoE++ at 802.3bt Type 3 is 60 W, and 4PPoE at 802.3bt Type 4 is 90 W over all four pairs, eight wires.
Now read the standard's own ladder. The IEEE 802 tutorial from July 2017 prints Type 3 at class 5 of 45 W port against 40 W device, class 6 of 60 against 51; Type 4 at class 7 of 75 against 62 and class 8 of 90 against 71.3, with minimum port voltages of 50 V and 52 V respectively, and it calls the port figure the worst case required to guarantee interoperability (Practical PoE tutorial, IEEE 802). It then works the worst case: 52 V across a channel resistance of 6.25 ohm gives 1.73 A, or 0.433 A per conductor, which the tutorial calls the highest nominal current in a compliant system.
Microchip's 802.3bt white paper prints the same ladder with device input minima of 3.84, 6.49, 13, 25.5, 40, 51, 62 and 71.3 W and then states the allowance in one sentence: "for a PSE sourcing 90W output, the PD should expect only 71W while 19W are budgeted for 100m cable power loss" (Next-Generation PoE white paper, Microchip). Nineteen watts of a ninety-watt port is a fifth of the number on the box, and it is spent before the device is reached.
Cisco prints the pair as well. The UPOE+ white paper carries a table pairing 15.4 W with 12.95, 30 with 25.5, 60 with 51 for both Cisco UPOE and 802.3bt Type 3, and 90 W with 71 W for Type 4 (Cisco UPOE+ white paper). The prose of the same paper gives 71.3 W for a class 8 device, and then, for Cisco UPOE, "60 watts ... from PSE and 54.4 watts to the PDs" against a table cell of 51 W. Three device-side numbers for one proprietary class, in one document: 51, 54.4 and the standard's own 51.
That is the first of the article's two numbers, and it is the one that belongs to the cable. My arithmetic, and it is mine and not Cisco's: 90 − 71.3 = 18.7 W, which is 20.8 per cent of the port figure, and the port figure is 90 / 71.3 = 1.262, or 26.2 per cent more than the device may ever draw. Put forty-eight of those ports in a chassis and the allowance alone is 48 × 18.7 = 897.6 W booked into the device rows of the table the switch accounts with. Nobody in the building will ever put a meter on that 897.6 W, because the standard has already granted it.
The number that decides how many ports you get is in footnote one
Here is the sentence that should be the headline of every Power over Ethernet data sheet, and is instead a footnote: "Limited by port number and port rating (for example, 24 PoE+ 30W ports = 720W)" (Catalyst 9200 data sheet). Cisco performs the multiplication that every buyer performs privately and almost nobody writes down: a port count times a per-port class figure is a load, and the load has to be paid for by a power supply.
On that same 9200 page the payment is visible. A C9200-24P gets 370 W of available PoE from one PWR-C6-600WAC and 740 W from two; a C9200-48P gets 740 W from one PWR-C6-1KWAC and 1,440 W from two; the 9200L models repeat the pattern, with the DC supplies producing 485 W on one PWR-C5-715WDC= and 740 W on two. The page also states that PoE+ allocation is dynamic and that power mapping "scales up to a maximum of 1440W of PoE+ power".
My arithmetic on Cisco's own footnote example: 24 × 30 W = 720 W, which sits between the 370 W one-supply budget and the 740 W two-supply budget, so the single-supply chassis pays for 370 / 30 = 12.33 ports at class maximum and the load is 720 / 370 = 1.95 times what that budget can carry. A compact C9200CX carries a 240 W internal PoE budget on a 315 W supply, which is the same story told smaller.
The 9300 page tells it harder. The C9300-48H is described as "48 ports Cisco UPOE+", and elsewhere the page advertises "48 ports of 90W Cisco UPOE+ in standalone mode". The table that governs says something else: "Cisco UPOE+ (90W per port) and IEEE 802.3bt Type 4 on 21 ports (24-port and 48port switch)" (Catalyst 9300 data sheet). Available PoE for that model is 1,622 W with one PWR-C1-1900WAC-P and up to 2,880 W with a second. My arithmetic: 48 × 90 = 4,320 W of port permission against a 2,880 W ceiling, a shortfall of 4,320 / 2,880 = 1.5, and the ceiling pays for 2,880 / 90 = 32 ports at the top class. Cisco's own answer is 21, which is 43.75 per cent of the chassis, and 21 × 90 = 1,890 W leaves 990 W of the 2,880 W ceiling unspent by that table's own ration. At 60 W Cisco UPOE the same page reaches all 24 ports of a 24-port model and up to 30 ports of a 48-port one.
The modular chassis is where the two numbers finally appear on the same page. The Catalyst 9400 line-card data sheet footnotes 226 ports supplying full 90 W concurrently at maximum power, with 231 for one supervisor combination, 240 for another and 229 for a third (Catalyst 9400 line-card data sheet). The chassis data sheet lists 384 × 802.3bt Type 4 ports at 90 W for a C9410R and repeats, in its own footnote, that 260 can supply full 90 W concurrently (Catalyst 9400 data sheet). My arithmetic: 384 × 90 = 34,560 W of port permission against 260 × 90 = 23,400 W of concurrent ration, a gap of 124 ports or 32.3 per cent of the density figure. Cisco's own conference deck states the same counts — 260 concurrent 90 W ports on a 9400, 288 in a 9300 stack with StackPower, 36 per C9300X-48HX (Catalyst Powered Smart Buildings, BRKENS-2091).
Note what has happened to the sentence. The density table sells a chassis. The footnote prices it. Between them sits the only question a network designer actually has: how many devices, at which class, will this box power at once. Across the seventeen documents I read on 26 November 2026, four of them answer that question for at least one configuration — the 9200 footnote, the 9400 line-card footnote, the 9400 chassis footnote and the conference deck — and none of those four states the supply combination and redundancy mode behind its own count.
The ration is a formula in three choices you make at the quote stage
A power supply is not a budget. It becomes one after the buyer decides how many to fit, at what site voltage the building runs, and whether the box must survive a supply failure. Cisco prints the conversion as arithmetic, which is unusually honest and unusually easy to miss.
On the 9400 data sheet, output power for PoE plus data is (3190 W × N)/2 + 10 W in N+N redundant mode at 230 VAC, (3190 W × (N−1)) + 10 W in N+1 mode, and (3190 W × N) + 10 W in combined mode, with 1,560 W substituted for 3,190 W at 115 VAC. The 2100 W AC supply yields 2,102 W at 230 V and 940 W at 115 V; the 3200 W DC supply yields 3,190 W. The architecture white paper gives the same ladder from the supply side — a 3200 W AC supply delivering 3,200 W at 240 V input and 1,570 W at 120 V, a 2100 W AC supply at 2,100 W or 940 W — and records that C9404R has four supply bays while C9407R and C9410R have eight, with N+N requiring an even number (Catalyst 9400 architecture white paper).
Run the formula for a four-bay chassis and the budget moves by a factor of two without a single part changing. My arithmetic: (3190 × 4)/2 + 10 = 6,390 W in N+N at 230 V; (1560 × 4)/2 + 10 = 3,130 W in N+N at 115 V; and (3190 × 4) + 10 = 12,770 W in combined mode at 230 V. At 90 W a port that is 71 ports, 34.7 ports and 141.9 ports respectively, against 192 physical ports on four 48-port cards.
The full count is worse than that: 192 ports at 90 W is 17,280 W of port permission, and with redundancy switched off those four supplies still give only 12,770 W, so the permission is 1.35 times what the chassis can pay. A buyer who reads "384 ports of 90 W" and a buyer who reads "260 concurrently" and a buyer who fits four supplies in a 115 V room and gets 34 ports are all reading the same product page.
The two documents also disagree about the chassis itself. The data sheet gives maximum PoE per slot as 4,320 W on the shipping line card with a chassis capability of about 4,800 W; the architecture paper lists PoE per slot as 4,800 W. Neither document reconciles the slot figure with the supply-derived budget, and a reader cannot: the line-card number and the supply formula live in different documents and are never joined in either.
What the queue does when the requests exceed the budget
The conversion from permission to claim happens at the moment a device is detected, and Cisco's configuration guide describes it as a queue rather than a calculation. Auto is the default. Power is granted first come, first served, and "if granting power exceeds the system's power budget, the device denies power, ensures that power to the port is turned off, generates a syslog message, and updates the LEDs. After power is denied, the device periodically rechecks the power budget and continues to attempt to grant the request for power" (Catalyst 9300 configuration guide, IOS XE 17.18.x).
Three other properties of that queue matter more than the denial itself. First, the switch tracks its budget and re-does the accounting every time a port is granted or denied, and the initial allocation is "the maximum power the powered device requires", later adjusted through CDP negotiation (Catalyst 9300 configuration guide, IOS XE 17.3.x). Second, static mode pre-allocates the configured maximum before a device is discovered, even with nothing plugged in, is not adjusted by IEEE class or CDP messages, and static ports are powered before auto ports. A port configured static holds its reservation against the global budget while the socket is empty and the janitor is vacuuming under it. Third, a device whose class maximum exceeds the port's configured maximum is given no power at all, and a device that draws more than its maximum has power removed and the allocation reclaimed.
Cisco's own troubleshooting document translates the failure for the operator: the denial message means "there is not enough power that remains in the switch to supply to the Power over Ethernet (PoE) port", the remedies are to check the budgeting, add supplies, change redundancy from redundant to combined, or pool power with StackPower, and the over-draw state appears as an err-disabled port with a SHUT_OVERDRAWN reason (Troubleshoot Power over Ethernet on Catalyst 9000, document 215636). The same page shows what the operator sees: show power inline printing Available, Used and Remaining watts per module and, per interface, Admin, Oper, Power, Device, Class and Max, with Max reading 60.0 W in the example.
So the buyer's arithmetic and the box's arithmetic meet in a log line. Nothing in the purchase documents tells the buyer how often a real floor plan hits that line; no page among the seventeen I read prints a denial rate, a retry interval or a queue depth. The behaviour is described precisely and the frequency is not described at all. And the configuration guide's stated range for a per-port maximum is 4,000 to 60,000 mW, which is release-specific wording that does not reach a 90 W UPOE+ port — a reminder that these port limits are firmware behaviour as much as standard behaviour.
The cable allowance, printed twice for the same access point
If the cable allowance were a fixed physical quantity, two documents describing one device would agree. Start with the device. The Catalyst 9136 access point draws a maximum of 47.3 W on 802.3bt, 24.4 W on 802.3at and 13.95 W on 802.3af with the radios off, and its own page advises enabling LLDP or CDP "for proper power negotiation" (Catalyst 9136 data sheet). The row carries no IEEE class number.
Now the controller guide, which prints consumption at the powered device against consumption at the power sourcing equipment "at worst-case cable": 13.9 W against 15.4 W for .3af fixed, 24.0 against 27.90 for .3at fixed, 43.4 against 54.81 for .3bt fixed, and 37.3 against 41.63 for .3bt under PoE policy 1 (Access point power save, Catalyst 9800 configuration guide). My arithmetic: 54.81 − 43.4 = 11.41 W at the device, and 41.63 − 37.3 = 4.33 W under policy 1. That is the cable allowance printed twice for one device at one standard, 7.08 W apart, and 11.41 W is 2.64 times the 4.33 W the same table prints under policy 1. The older standards scale the same way: 15.4 − 13.9 = 1.5 W at .3af and 27.90 − 24.0 = 3.9 W at .3at. What a switch reserves when the 9136 arrives, and which of those two allowances the reservation assumes, is not stated on either page.
The reservation is a different quantity from the draw in any case. A device drawing 24.4 W under .3at holds a class-4 port permission of 30 W, so 30 − 24.4 = 5.6 W, or 18.7 per cent of the reservation, sits above its printed maximum. On 802.3bt the 47.3 W figure against a class-8 permission of 90 W leaves 90 − 47.3 = 42.7 W, 47.4 per cent of the permission, unclaimed by that device. The reservation is the class; the draw is the workload; the difference is the switch's problem.
The cleanest comparison in the whole corpus is a camera. The 8630 network camera supports PoE 802.3at Class 4, and prints maximum consumption of 19.5 W on DC, 21.8 W on AC and 24.8 W on PoE (Cisco 8630 camera data sheet, C78-739361-00, 07/17). It is the only powered device among the seventeen documents that prints a class number, a port permission and its own draw on one page. My arithmetic: 24.8 W sits 5.2 W under the 30 W port permission and 0.7 W under the 25.5 W device-side allowance, which is 97.3 per cent of what the standard permits at the far end while the port reserves 30 W. Two notes belong beside that number: the document is dated 2017 and was read from a reseller-hosted copy of Cisco's own PDF because the cisco.com path returned nothing on the day, and a camera with a heater is exactly the kind of load whose maximum is a cold-morning number rather than an afternoon number.
The cable is derated for heat, not for watts
The one place Cisco sells the cable as a constraint is the 9400 hardware installation guide's appendix on 802.3bt cabling. It tabulates current per port and per conductor: 802.3af at 350 mA and 175 mA, 802.3at at 600 and 300, Cisco UPOE at 1,200 and 300, and 802.3bt at 1,732 and 433 (Catalyst 9400 hardware installation guide, cabling appendix). Systems at or below 0.3 A per conductor on 24 AWG or larger are exempt from further analysis, which clears 802.3af, 802.3at and Cisco UPOE and leaves Type 4 as the only class that needs the analysis. A bundle is defined as cables tied together or in contact in a closely packed configuration for at least 1.0 m. The recommendation that follows is Category 6A rated 75 °C, 23 AWG, in bundles of 192 or fewer, derived from NEC 2020 Table 725.144 adjusted to a 45 °C ambient.
The UPOE+ white paper gives the same guidance as a ladder: 24 AWG at 60 °C in bundles of 37 or fewer, 23 AWG at 60 °C up to 61, 24 AWG at 75 °C up to 91, and 23 AWG at 75 °C up to 192. Two Cisco documents, two presentations of one NEC table, agreeing.
Read the limit's subject carefully, because this is where a reader's instinct misleads. The derating is not a function of the watts on the pair; it is a function of the current in the conductor and the heat it cannot shed in a bundle. Type 4's 433 mA per conductor crosses the 0.3 A exemption line, and that is the only reason the analysis exists. A purchaser who specifies Cat 6A 75 °C 23 AWG has satisfied the constraint without ever computing the 18.7 W allowance, and a purchaser who specifies the same cable in a bundle of 300 has failed it without changing a single port's power.
The watts are the standard's business; the heat is the electrician's.
What a reader can recompute
Here is the test I set before I started reading, and here is how it came out across seventeen documents read on 26 November 2026. Name the page that prints the class table with both watt columns: Cisco's UPOE+ white paper does, 15.4/12.95, 30/25.5, 60/51 and 90/71, with the prose contradicting its own 51 W cell at 54.4 W. Name the page that prints a switch's total budget: every data sheet prints an available-PoE table, keyed to a supply combination the buyer selects. Name the page that prints port count and per-port class maximum: every data sheet does.
Name the page that multiplies them: the 9200 footnote, and only the 9200 footnote, does it in public. Name the page that prints the supply rating the budget is drawn from: the 9400 does, as a formula in N. Name the page that prints the allocation rule: the configuration guides do, in three modes. Name the page that prints what happens when the budget is spent: the 17.18 guide and the troubleshooting document do, as a syslog line, an LED and a retry. Name the page that prints the cable assumption behind the class gap: Microchip does in one sentence, and Cisco's own table does not put a length or a gauge beside the 18.7 W.
Name the page with a named device's class and draw: the 8630 camera does, and it is a 2017 sheet read from a reseller copy. Name the page that joins a named switch's supply configuration, budget, port count, class maximum and a worked count of ports at that class: none of the seventeen does, and four documents come close enough that a reader can finish the division.
That last sentence is the finding, and it is deliberately narrow. It is a count of documents read on a date, not a claim about what exists. What the count establishes is the shape of the product: a permission at the port, a ration at the box, a queue between them, and an allowance for the cable that one vendor prints in a device-side column and then charges to the switch's budget anyway.
Why does the shape matter beyond a data sheet? Because the devices at the end of the cable grew hungrier than the classes did. An access point that once ran on 12.95 W now ships a generation that asks for the top class; a camera added a heater for cold mornings; a desk phone became a video terminal. Every one of those is a reservation against a budget the building sized before they existed. The failure does not arrive as a warning at the point of sale. It arrives as one port on a floor that will not come up, a syslog line nobody is watching, and an electrician being asked whether the cable is faulty.
It is not the cable. It is a queue, and the buyer was never shown the queue's length.
The practical instruction is small and unfashionable: make the vendor do the division in writing, for the configuration you are actually buying, at the voltage your building actually has, in the redundancy mode your resilience policy actually requires. The 9200 footnote is the template. One sentence, one multiplication, one budget, one number of ports. Everything else on the page is a permission. A permission is not a delivery, and a budget is not a promise until somebody multiplies.
Cisco Systems, Inc. has its own entry in the BTW directory (the Cisco entry at btw.media), and this house's earlier coverage of the company does not touch this question: five articles, the nearest an unpublished briefing on Cisco's throughput tables divided by a divisor no table prints, plus published pieces on Meraki licence renewal dates, IOS XR maintenance releases and two PSIRT scope changes. None of them reads a watt. What comes close is my own work on other subjects: a buried cable whose ampere rating is fixed by a soil the standard delegates to the buyer, a rack PDU whose amperage is the plug rather than the load, and a processor whose printed watt is a permission to cool. This piece takes the one cable that carries data and power at once, and asks which of its three watts the building pays for.
Member Briefing
Read the full trend briefing
Members read the full briefing with the source notes behind every finding.
Strategic Circle
A daily briefing in your language, built from changes we have verified.
Join for USD 20/monthCancel anytime.
Members also get the full research library, a daily briefing on the networks they follow and the private forum.