Summary
- Backblaze's 2025 annual failure rate of 1.36% rebuilds exactly from three printed numbers — 4,317 failed drives, 115,638,676 drive days and 30 drive models — because the page prints the formula, the unit of exposure and its exclusions in the same place.
- The 99.999999999% durability claim is a Poisson model fed by a 0.81% drive AFR discounted to 0.41% for data-recovery services, about a third of the failure rate the same company measures on its own fleet, and its "1 file in 10 million years" illustration is short by two orders of magnitude of nines.
Backblaze Inc — its entity record — publishes two statements about the same spinning disks, and they are not the same kind of object. The first is a rate: for 2025, 1.36% of drives failed on an annualised basis across 30 drive models. The second is a promise: 99.999999999% annual durability for data held in B2.
One of those numbers can be rebuilt on a napkin by anyone with the page open. The other cannot be tested inside a customer's lifetime, and the assumption it rests on is printed two paragraphs down — where it turns out to be about a third of the failure rate the same company reports for its own fleet.
The half that is auditable
Start with the method. The drive-stats explainer prints the formula itself: "AFR = ( drive_failures / ( drive_days / 365 )) * 100" (Q2 2022 report), then names the terms. The denominator is defined as "drive_days: The number of days all of the drives in the selected cohort are operational during the defined period of time of the cohort", and the unit is put in plain language elsewhere: "A drive day is one drive in operation for one day, so one drive in operation for ten days is ten drive days." (ten years of drive stats).
That is unusually complete. Numerator, denominator, unit, period and cohort are all printed, which is why the published rate is checkable rather than merely quotable. My division: 115,638,676 drive days divided by 365 is 316,818.3 drive-years; 4,317 failures divided by that is 0.013626, or 1.36% (2025 annual report). The published figure and the recomputed one agree to the printed precision.
The same check works on the other period rows. The Q2 2026 snapshot prints 354,415 drives, 31,553,350 drive days and 1,498 failures; the arithmetic gives 1.73% (drive-stats landing page). The lifetime line on that page prints 21,609 failures over 558,148,607 drive days, which is 1.41% by my arithmetic.
Two documents, one word: the January 2026 release announcing the 2025 report prints the lifetime rate as 1.30% (the release), while the landing page prints 1.41% for what reads as the same lifetime line. Neither page carries a sentence reconciling the two, and I could not close the gap from the printed operands. The scope of that gap is the pages I read on 24 November 2026, not every document the company has published.
Whose drives are in the count
The rate is auditable only because the exclusions are printed too. The Q3 2024 report is explicit: "For our Q3 2024 quarterly analysis, we remove the following from consideration: drive models which did not have at least 100 drives in service at the end of the quarter, drive models which did not accumulate 10,000 or more drive days during the quarter, and individual drives which exceeded their manufacturer’s temperature specification during their lifetime." (Q3 2024 report).
The thresholds are not constant. The quarterly rule above is 100 drives in service at quarter end and 10,000 drive days inside the quarter; the annual cohort needs more than 250 drives and more than 50,000 drive days; the lifetime cohort more than 500 drives and more than 100,000 lifetime drive days (2025 annual report). Earlier, the bar was lower and worded differently: drive models with fewer than 60 drives were removed (Q1 2020 report). Read in sequence, the three sets say something simple. The population is drawn at the analysis stage, and the bar rises as the fleet grows.
Then there are the drives set aside for other reasons. The 2025 report prints the monitored fleet and the removals in one breath: "As of the end of 2025, Backblaze was monitoring 341,664 drives used to store data. For our evaluation, we removed from consideration 4,013 boot drives and 459 hard drives, as they did not meet the criteria to be included." (2025 annual report). The same page's annual table carries 344,196 drives — 2,532 more than the monitored storage figure by my subtraction. No sentence on the page says the two counts describe the same population, and I will not invent the bridge: a period cohort counts drives that appeared in that period, a year-end figure counts drives present on one day, and only the second of those is actually stated.
The downloadable file and the published rate are also different objects, and Backblaze says so plainly: "All line-item data, including drives excluded from report tables, is included in the downloadable Drive Stats dataset." (2025 annual report). A reader who wants the excluded drives can have them. What the reader cannot have is a published rate computed over them.
Who counts a failure
The numerator has its own counting rule, and it is a presence test: "A drive is classified as failed when it either appears in data center work tracking systems or hasn’t re-entered the active population by quarter’s end." (Q3 2025 drive-stats release). The first clause routes the numerator through the company's own maintenance records. The second defines a failure by absence at a date.
The consequence shows up in the company's own prose, in the most candid paragraph of the corpus: "The Toshiba MG08ACA16TEY (16TB) recorded a 16.95% AFR in Q3 2025 because an upgrade required temporary removal, not because of mechanical issues. Backblaze expects the affected AFR to normalize in future reports." (Q3 2025 drive-stats release). A drive sitting in a maintenance bay counts as a failure for the quarter it missed. The rate is not wrong; it is a rate over a population that an upgrade schedule can move.
One further property of the denominator is worth carrying. The Q2 2026 snapshot's 31,553,350 drive days over 354,415 drives is about 89 days of exposure per drive, against a quarter of 91 days (my arithmetic). The average drive in the reported cohort was not there for the whole period — which is exactly what a drive-day denominator exists to handle, and exactly why the drive count printed beside it is not the denominator.
The half that is a model
Now the other number. "At the end of the day, the technical answer is “11 nines.” That’s 99.999999999%. Conceptually, if you store 1 million objects in B2 for 10 million years, you would expect to lose 1 file." (durability explanation).
Take the illustration seriously and it breaks. Eleven nines is a one-in-one-hundred-billion annual probability of loss. One million objects held for ten million years is 10^13 object-years. Multiply the two and about 100 objects are expected to be lost, not one (my arithmetic). For the sentence to hold, the annual figure would have to be thirteen nines.
The page itself records an internal per-interval result of twelve nines before annualising and counts 56 rebuild intervals in that annualisation; 56 times one in a trillion is 5.6 in 100 billion, a little over ten and a quarter nines, not eleven (my arithmetic, from the page's own two printed values). The published figure is more optimistic than the annualised sum of the page's own per-interval number.
The load-bearing assumption is printed, which is the good news: "The Poisson calculation assumes 6.5 days average rebuild time and a 0.81% drive AFR, reduced to 0.41% by assuming 50% likelihood of full data recovery from a failed drive via services such as DriveSavers." (durability explanation).
Compare that with the audited half. The model runs on 0.41% after the recovery discount; the measured 2025 fleet rate is 1.36%. The assumption is about a third of the measurement; the measured rate is about 3.3 times the discounted assumption, and about 1.7 times the 0.81% before the discount (my arithmetic). No sentence in the ten pages I read reconciles those numbers, and none states which period the 0.81% describes. A reader may reasonably guess it is a conservative long-run figure. The page does not say so, and the company's own reporting for the same fleet is higher in every period I checked.
The geometry, at least, is stated. "Each file is stored as 20 shards: 17 data shards and 3 parity shards." (vault architecture). Twenty locations, seventeen of them data: three simultaneous losses can be reconstructed, a fourth destroys the file (my arithmetic).
What a reader can hold
Two habits follow, and both are cheap. When a vendor prints a rate, look for the four things Backblaze prints — numerator, denominator, unit and exclusion list — and if they are all there, do the division yourself. When a vendor prints nines, look for the model's inputs. Here the input is a drive failure rate lower than the one the same company measures on the same kind of hardware, and the illustration attached to the number needs two more nines than the number does.
That is not a scandal. It is a specification. The drive report is a measurement with its working shown; the durability claim is a calculation with one input borrowed and one discounted by half. Buyers who can tell which is which will ask sharper questions, starting with which period the 0.81% came from.
Member Briefing
Read the full trend briefing
Members read the full briefing with the source notes behind every finding.
Strategic Circle
A daily briefing in your language, built from changes we have verified.
Join for USD 20/monthCancel anytime.
Members also get the full research library, a daily briefing on the networks they follow and the private forum.






